Cobra Electronics 148.GTL.ST operating instructions Section IV Operation

Page 10

148.GTL.ST.MANUAL 10/1/98 10:56 AM Page 19

Section IV Operation (Continued)

Fig. 2. Microphone Cable Preparation

To wire the microphone cable to the plug provided, proceed as follows.

34

2 1

Fig. 3. Microphone plug wiring.

1.Remove the retaining screw.

2.Unscrew the housing from the pin receptacle body.

3.Loosen the two cable clamp retainer screws.

4.Feed the microphone cable through the housing, knurled ring and washer as shown Fig. 3B.

5.The wires must now be soldered to the pins as indicated in the above wiring tables. If a vise or clamping tool is available it should be used to hold the pin receptacle body during the soldering operation, so that both hands are free to perform the soldering. If a vise or clamping tool is not available, the pin recep- tacle body can be held in a stationary position by inserting it into the micro- phone jack on the front panel. The numbers of the pins of the microphone plug are shown in Fig 4, as viewed from the back of the plug. Before soldering the wire to the pins, pre-tin the wire receptacle of each pin of the plug.

16

Section IV Operation (Continued)

Fig. 4. Microphone plug pin numbers viewed from rear of pin receptacle.

Be sure that the housing and the knurled ring of Fig. 3 are pushed back onto the microphone cable before starting to solder. If the washer is not captive to the pin receptacle body, make sure that it is placed on the threaded portion of the pin receptacle body before soldering.

If the microphone jack is used to hold the pin receptacle during soldering opera- tion, best results are obtained when the connections to pins 1 and 3 are made first and then the connections to pins 2 and 4. Use a minimum amount of solder and be careful to prevent excessive solder accumulation on pins, which could cause a short between the pin and the microphone plug housing.

6.When all soldering connections to the pins of the microphone are com- plete, push the knurled ring and the housing forward and screw the housing onto the threaded portion of the pin receptacle body. Note the location of the screw clearance hole in the plug housing with respect to the threaded hole in the pin receptacle body. When the housing is completely threaded into the pin receptacle body, a final fraction of a turn either clockwise or counterclockwise may be required to align the screw hole with the threaded hole in the pin receptacle body. When these are aligned, the retaining screw is then screwed into place to secure the housing to the pin receptacle body.

7.The two cable clamp retainer screws should now be tightened to secure the housing to the microphone cord. If the cutting directions have been careful- ly followed, the cable clamp should secure to the insulation jacket of the microphone cable.

8.Upon completion of the microphone plug wiring, connect and secure the microphone plug in the transceiver.

17

Image 10
Contents Citizens Band SSB/AM 2-WAY Mobile Radio CB Story SSB/AM 2-WAY Mobile RadioFrequency Range Section II SpecificationsSection I Introduction GeneralPA System Section III InstallationReceiver LocationIgnition Noise Interference Tuning the Antenna for Optimum SWRAntennas with adjustable screws set screws AntennaExternal Speaker Controls and IndicatorsSection IV Operation Public AddressSection IV Operation Operating Procedure to Transmit Indicator FunctionsOperating Procedure to Receive Receiving SSB SignalsAlternate Microphones and Installation Wire MIC CableSection IV Operation How SoundTracker Works Section V Maintenance and AdjustmentFCC Warning Code Activating/Testing SoundTrackerSection VI Appendix Code MeaningUSE Channel 9 for Emergency Messages only FEW Rules That should be ObeyedHOW Your CB can Serve YOU Permitted Example MessageCobra Electronics Corporation If You Think You Need Service6500 W. Cortland Street Chicago, Illinois Mail to Order by phoneFax to