Philips 232801 manual Lamp Operating Instructions

Page 2

Philips Lighting Company

www.philips.com

Philips Lighting

200 Franklin Square Drive

 

281 Hillmount Road

P.O.Box 6800

 

Markham, Ontario

Somerset, NJ 08875-6800

 

Canada L6C 2S3

1-800-555-0050

 

1-800-555-0050

A Division of Philips Electronics North America Corporation

A Division of Philips Electronics Ltd.

Updated 1/09

TDS-232801

 

Pulse Start Universal Metal Halide 250 Watt Lamp (Clear)

Electrical Data (Subject to change without notice )

Lamp Watts (Nominal)

250

Lamp Operating Voltage (rms) (Nominal)3

133

Initial Lamp Voltage Range (rms)6

120-140

Lamp Operating Current (Amps) (rms) (Nominal)

2.0

Lamp Current Crest Factor (Maximum)

1.6

Warm-up Time to 90% of Output

2 Minutes

Re-strike Time for Hot Lamp

4 Minutes

Ballast Type

ANSI M153/M138/E

Ballast Open Circuit Voltage (Minimum)

250 RMS Min.

Pulse PeakVolts

3000 Minimum, 4000 Maximum

Pulse Width @ 90% Peak

1.3 Micro Second Minimum

Pulse Repetition Rate (Minimum)

1 per Half Cycle

Minimum Operating Temperature

-30º C (-22°F)

Philips Lighting Electronics Ballast Number

71A5793

1)Approximate lumen values listed are for horizontal operation of the lamp.

2)Measured at 100 hours of life in horizontal position.

3)Measured at rated lamps on a linear reactor. LPW does not include ballast losses.

4)Approximate lumen output at 40% of lamp rated average life.

5) Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start. It is based on survival of at least 50% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average.

6) Measured with the lamp operation at rated watts.

Warnings, Cautions and Operating Instructions

R“WARNING:These lamps can cause seriousskin burn and eye inflammation from short wave ultravioletradiationif outer envelopeof the lamp is brokenor punctured.Do not use where people will remainfor more than a few minutesunless

adequateshieldingor other safetyprecautionsare used.Certain lamps that will automaticallyextinguishwhen the outer envelopeis brokenor puncturedare commerciallyavailable." This lamp complieswith FDA radiationperformance standard21 CFR subchapterJ. (USA:21CFR1040.30Canada:SOR/DORS/80-381)

If the outer bulb is brokenor punctured,turn off at once and replace the lamp to avoid possible injury from hazardousshort wave ultraviolet radiation.Do not scratch the outer bulb or subject it to pressureas this could cause the outer bulb to crack or shatter.A partial vacuum in the outer bulb may cause glass to fly if the envelope

is struck.

WARNING:The arc-tubeof metal halide lamps are designed to operate under high pressureand at temperaturesup to 1000ºC and can unexpectedlyrupture due to internal or external factors such as a ballast failure or misapplication. If the arc-tube rupturesfor any reason,the outer bulb may break and pieces of extremely hot glass might be dischargedinto the surroundingenvironment.If such a rupture were to happen,THERE ISA RISK OF PERSONALINJURY,PROPERTY

DAMAGE,BURNSAND FIRE.

Certain lamps that will retainall the glass particlesshould inner arc-tube ruptureoccur are commerciallyavailablefrom PhilipsLightingCompany.

RELAMP FIXTURESATOR BEFORETHE END OF RATEDLIFE. Allowinglamps to operateuntil they fail is not advisedand may increase the possibilityof inner arc tube rupture.

CAUTION: TO REDUCETHE RISK OF PERSONALINJURY,PROPERTY DAMAGE,BURNSAND FIRE RESULTINGFROMAN ARC-TUBERUPTURETHE FOLLOWINGLAMP OPERATINGINSTRUCTIONSMUST BE FOLLOWED.

Lamp Operating Instructions:

1)Turnoff lamps at least once a week for at least 15 minutes in systems which are operating on a continuous basis (24 hours/day-7days/week)FAILURETOTURN. OFF LAMPS FORTHE MINIMUM RECOMMENDEDTIME MAY INCREASE THE POSSIBILITY OF AN INNERARC-TUBE RUPTURE.

2)RELAMP FIXTURESAT OR BEFORETHE END OF RATEDLIFE.Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.

3)Use only in an enclosed fixture capable of withstandingparticles of glass having temperaturesup to 1000ºC.

4)Before lamp installation/replacement,shut power off and allow lamp and fixture to cool to avoid electrical shock and potential burn hazards.

5)Use only auxiliary equipment meeting Philips and/orANSI standards.Use within voltage limits recommendedby ballast manufacturer.

A.Operate lamp only within specified limits of operation.

B.For total supply load refer to ballast manufacturerselectrical data.

C.All Pulse Start mogul based lamps require a socket rated to withstand a 4000 volt pulse.

6)Periodicallyinspect the outer envelope.Replace any lamps that show scratches, cracks or damage.

7)If a lamp bulb support is used,be sure to insulate the support electricallyto avoid possible decompositionof the bulb glass.

8)Protect lamp base, socket and wiring against moisture,corrosiveatmospheres and excessive heat.

9)Time should be allowed for lamps to stabilize in color when turned on for the first time.This may require several hours of operation,with more than one start. Lamp color is also subject to change under conditions of excess vibration or shock,and color appearance may vary between individual lamps.

10)Lamps may require 2 to 10 minutes to re-light if there is a power interruption.

11)Takecare in handling and disposing of lamps. If an arc tube is broken,avoid skin contact with any of the contents or fragments.

12)Use this lamp only in fixtures that contain a Pulse Start metal halide ballast and are specificallydesigned for use with Pulse Start metal halide lamps.

Image 2
Contents Ordering Information Physical CharacteristicsOperating Characteristics Photometric Operating PositionLamp Operating Instructions

232801 specifications

The Philips 232801 is a monitor that stands out in both performance and design, catering to a wide range of users, from casual consumers to professional designers. One of the key features of the Philips 232801 is its impressive display technology. The monitor is equipped with an IPS panel, which ensures vibrant colors and wide viewing angles. This makes it particularly appealing for tasks that require color accuracy such as photo editing, graphic design, and video production.

The screen size of the Philips 232801 is 23 inches, providing ample screen real estate while remaining manageable for desk setups. With a Full HD resolution of 1920x1080 pixels, it delivers sharp and clear visuals suitable for both productivity tasks and media consumption. The monitor's slim bezels enhance the immersive experience, allowing users to engage more deeply with their content.

Another significant characteristic of the Philips 232801 is its commitment to eye care. It incorporates several technologies designed to reduce eye strain during prolonged usage. Features such as LowBlue Mode and Flicker-Free technology help in minimizing harmful blue light and screen flickering, promoting a more comfortable viewing experience. This is especially advantageous for those who spend long hours in front of their screens.

Connectivity is another strong suit of the Philips 232801. It comes equipped with multiple input options including HDMI and VGA ports, making it compatible with a variety of devices, from PCs to laptops and gaming consoles. This versatility allows users to connect effortlessly to their preferred gadgets.

The design of the Philips 232801 is not only functional but aesthetically pleasing as well. It features an elegant stand that allows for tilt adjustments, ensuring optimal viewing angles. The monitor's sleek design can easily complement any office or home setup.

In conclusion, the Philips 232801 monitor is a robust choice for anyone in need of a reliable, high-quality display. With its IPS technology, Full HD resolution, multiple connectivity options, and eye care features, it strikes a fine balance between performance and user comfort. Whether for work, study, or entertainment, the Philips 232801 aims to deliver an excellent viewing experience while being mindful of users' health and comfort.