Nordyne R-410A To Operate Your Heat Pump for Automatic Cooling Heating, To Shut Offyour Heat Pump

Page 4

of snow and ice on the heat transfer coil. This is normal, and the unit will periodically defrost itself. During the defrost cycle, the outdoor fan will stop, and the compressor will continue to run and heat the outdoor coil, causing the snow and ice to melt. After the snow and ice have melted, some steam may rise from the outdoor unit as the warm coil causes some melted frost to evaporate.

TO OPERATE YOUR HEAT PUMP FOR AUTOMATIC COOLING AND

HEATING —

1.Set the thermostat system switch to AUTO and the thermostat fan switch to AUTO.(See

Figure 1)

Note: Thermostats will vary. Some models will not include the AUTO mode, and others will have the AUTO in place of the HEAT and COOL, and some will include all three.

2.Set the thermostat temperature to the desired heating and cooling temperature level(s). The outdoor unit and the indoor blower will then cycle on and off in either the heating or cooling mode of operation as required to automatically maintain the indoor temperature within the desired limits.

TO SHUT OFFYOUR HEAT PUMP —

Set the thermostat system switch to OFF and the thermostat fan switch to AUTO. (See Figure

1)The system will not operate, regardless of the thermostat temperature selector(s) setting.

TO OPERATE THE INDOOR

BLOWER CONTINUOUSLY —

Set the thermostat fan switch to ON (See Figure 1). The indoor blower will start immediately, and will run continually until the fan switch is reset to AUTO.

The continuous indoor blower operation can be obtained with the thermostat system switch set in any position, including OFF.

The continuous indoor blower operation is typically used to circulate the indoor air to

equalize a temperature unbalance due to a sun load, cooking, or fireplace operation.

TO MAINTAIN YOUR HEAT PUMP —

CAUTION:

Be certain the electrical power to the outdoor unit and the furnace/air handler is disconnected before doing the following recommended maintenance.

1.Regularly:

a.Clean or replace the indoor air filter at the start of each heating and cooling season, and when an accumulation of dust and dirt is visible on the air filter. Inspect the filter monthly.

b.Remove any leaves and grass clippings from the coil in the outdoor unit, being careful not to damage the aluminum fins.

c.Check for any obstruction such as twigs, sticks, etc.

CAUTION:

Do not over-oil, or oil motors not factory-equipped with oil tubes. The compressor is hermetically “sealed” and does not require lubrication.

2.Before Calling a Service Technician, Be Certain:

a.The unit thermostat is properly set — see “To OperateYour Heat Pump for Cooling” and “To Operate Your Heat Pump for Heating.”

b.The unit disconnect fuses are in good condition, and the electrical power to the unit is turned on.

Read Your Warranty

Please read the separate warranty document completely. It contains valuable information about your system.

4

Image 4
Contents Winter Heating Summer CoolingPage To Operate Your Heat Pump For Heating See FigureEmergency Heat DefrostTo Operate Your Heat Pump for Automatic Cooling Heating To Shut Offyour Heat PumpTo Operate the Indoor Blower Continuously To Maintain Your Heat PumpGeneral Information Safety ConsiderationsSite Preparation Installing the Indoor Unit Installing the Outdoor UnitElectrical Connections Copper Wire Size AWG Startup and CheckoutStat is used BetweenW2 and E isFor 2-Stage Heater Kits Air Handler Comfort AlertTM Diagnostics Select Models LED Description See FigureTroubleshooting Interpreting the Diagnostic Leds RedTRIPDefrost Test Procedure Module Wiring TroubleshootingOutdoor Thermostat if supplied Anti Short Cycle Timer Test Seer Split System Heat Pump Orifice Usage018K 024K 030K036K 042K048K 060KOutdoor Temperature DEG. F Outdoor Temperature DEG. F 042K 060K Page ¢708410p¤
Related manuals
Manual 20 pages 19.69 Kb Manual 20 pages 6.05 Kb

R-410A specifications

Nordyne R-410A is a widely recognized refrigerant used in modern air conditioning and heat pump systems, known for its efficiency and environmentally friendly attributes. As a hydrofluorocarbon (HFC) refrigerant, R-410A has become the preferred choice for many manufacturers seeking to meet stringent environmental regulations while providing superior cooling performance.

One of the main features of R-410A is its higher energy efficiency compared to older refrigerants like R-22. This efficiency is primarily attributed to its higher pressure capabilities, which allow for improved heat transfer and reduced energy consumption in residential and commercial systems. As energy costs continue to rise, the use of R-410A in HVAC systems offers a viable solution for reducing utility bills while maintaining optimal comfort levels.

R-410A is also non-ozone-depleting, which sets it apart from many traditional refrigerants. While older refrigerants have been phased out due to their potential harm to the ozone layer, R-410A presents a sustainable alternative that aligns with environmental goals. It features a zero ozone depletion potential (ODP), making it a responsible choice for installations concerned with ecological impact.

In terms of technology, R-410A works effectively in both air conditioning and heat pump systems, providing reliable cooling in hot conditions and heat in colder months. It is compatible with a variety of system designs and can excel in both residential and commercial applications. Moreover, the thermodynamic properties of R-410A ensure consistent and reliable performance, regardless of the external temperature fluctuations.

Another characteristic of R-410A is its ability to operate at lower temperatures, which enhances its versatility. This capability allows for the design of systems that can function efficiently in a wider range of climate conditions. As a result, HVAC technicians and contractors benefit from its reliability and performance, leading to less frequent maintenance and enhanced customer satisfaction.

Lastly, R-410A systems are equipped with advanced components that improve overall functionality. These systems often include variable-speed compressors, which optimize energy use based on cooling demand, and advanced refrigerant management technologies that ensure safe and efficient operation.

In conclusion, Nordyne R-410A stands out as a superior refrigerant due to its energy efficiency, environmental benefits, and adaptability across a range of HVAC applications. As the industry continues to innovate and shift toward sustainable solutions, R-410A remains at the forefront of refrigerant technology, ensuring homeowners and businesses alike enjoy efficient and eco-friendly cooling options.