INSTALLATION INSTRUCTIONS
The humidistat is designed for either return air duct or wall mounting. Packaged in a duct mount configuration, (For this type mounting begin installation at the section labeled return air duct installation on page 2.) for conversion to a wall mount configuration simply pull off the knob and remove the mounting screws and rotate the control 180° and reattach the mounting base, (For this type mounting begin installation at the section labeled wall mount installation on page 3.).
DANGER
∗Do not cut or drill any
∗Fatal electrocution is possible if you contact a live wire.
∗Electrical power can cause electrical shock
∗Disconnect all electrical power supplied to the equipment before beginning installation.
∗Blindness can occur if freon contacts your eyes.
CAUTION
∗Do not install on any electrical system over 30 VAC
CAUTION
∗All electrical wiring should comply with codes and ordinances.
Recommended Settings | Warning: | ||
At Outside Temperatures | Recommended Setting | Adjusting the | |
|
| ||
15% | humidity control | ||
20% | higher than the rec- | ||
0°F | 25% | ommended setting | |
may cause conden- | |||
+10°F | 30% | ||
sation resulting in | |||
|
| ||
+20°F | 35% | possible damage to | |
Over 20°F Over 0°C | 40% | the home. |