9.OPERATION

9.3 Auto, Cool, Heat, Dry, Fan Mode

Heat Mode:

1.Plug the Power Cord into the power outlet.

2.Turn on the unit by pressing the ON/OFF Button on the Control Panel.

3. Press the Mode Button until signal “

“ appears on the display.

4.Set the room temperature to your desired room temperature with Temperature Changing Button.

Then set temperature range from 60°F to 82°F.

We recommend temperature for your comfort between 69°F to 75°F.

5.Select the fan speed by pressing the Fan Speed Button. It is recommended to use a low fan setting.

The Heating Function is provided by an electric heat element. The compressor will not operate in HEAT Mode. It is not necessary to connect any of the exhaust hoses to the unit.

Dry Mode:

1.Plug the Power Cord into the power outlet.

2.Turn on the unit by pressing the ON/OFF Button on the Control Panel.

3.Press the Mode Button until the signal “ “ appears on the display.

4.Set the room temperature to your desired room temperature with temperature change button.

5.Keep the windows and the doors closed to aid the effectiveness.

6.The unit will only operate at low fan speed in Dry Mode. It is recommended not to install the exhaust hose for the best dehumidifying effect; however, the room may become too warm for comfort. In this case, the exhaust hose should be used.

NOTE: The unit will not perform dehumidifying when the room temperature is lower than 64°F.

Fan Only Mode:

1.Plug the Power Cord into the power outlet.

2.Turn on the unit by pressing the ON/OFF Button on the Control Panel.

3.Press the Mode Button until signal appears on the display.

4.Select the fan speed by pressing the Fan Speed Button.

15

Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203

Image 15
Contents Model PE-91A PE-121A Cool Heat DehumidifyIndex Operation12-17 For Future REFERENCE, Please Record the Following Customer ServiceBefore USE If you need assistance, please callQuick SET UP Suggestions for USE IntroductionPE-91A / PE-121A SpecificationsParts & Accessories Do not SafetyDo not USE if Above Test Fails SafetyPlug Testing Instructions Call Customer Service if Test FailsInstallation Kit Air Inlet & Air Outlet Hose 2 sets InstallationVerticalhorizontal Installation ProceduresControl Panel and Display OperationRemote Controller Auto, Cool, Heat, Dry, Fan Mode Auto ModeCool Mode Heat Mode Dry ModeFan Only Mode ON-TIMER Program Setting Timer Setting ProcedureAir Flow Direction Control Horizontal Swing StripVertical Swing Strip Condensate Disposal Drain Excess Condensate WaterLong-Term Storage MaintenanceClean the Filter Clean Exterior Surface of the UnitStoring the Power Cord Problem Cause Solution Trouble ShootingPower Supply Wiring DiagramQuality Leader in Conditioning AIR

PE-91A PE-121A specifications

The Heat Controller PE-91A and PE-121A represent advanced solutions in the realm of heating and cooling technology. These units have gained recognition for their performance, reliability, and energy efficiency, making them suitable for a range of residential and commercial applications.

One of the standout features of the PE-91A and PE-121A models is their inverter technology, which allows for precise temperature control. This technology works by adjusting the compressor speed based on the heating or cooling requirements, leading to less energy consumption compared to traditional systems. As a result, users benefit from lower utility bills while maintaining optimal comfort levels throughout their living or working spaces.

Both models are equipped with a high-efficiency air filter that improves indoor air quality by capturing dust, allergens, and other particulate matter. This feature is particularly beneficial for individuals who suffer from allergies or respiratory issues, providing them with cleaner and healthier air. Furthermore, the filters are designed for easy removal and cleaning, ensuring minimal maintenance hassle for users.

The PE-91A and PE-121A also incorporate advanced climate control technologies. The units feature programmable timers and digital thermostats, allowing users to set schedules that accommodate their lifestyles. Whether it’s cooling down before arriving home or warming up a space early in the morning, these programmable settings enhance convenience and energy savings.

In terms of design, both models are sleek and compact, making them suitable for various installation environments. Their modern aesthetics allow them to blend seamlessly with existing decor, while their lightweight construction simplifies the installation process.

Another significant aspect of these models is their quiet operation. Utilizing advanced sound-dampening technology, the PE-91A and PE-121A operate at minimal noise levels, which is crucial for residential areas or places of business where noise can be a distraction.

Furthermore, both units are designed with durability in mind. They feature robust construction that withstands fluctuating weather conditions, ensuring longevity and reliable performance over time.

In summary, the Heat Controller PE-91A and PE-121A offer a blend of efficiency, advanced technology, and user-friendly features, making them excellent choices for anyone looking to enhance their heating and cooling systems while ensuring comfort and cost-effectiveness. With these units, users find a perfect balance between modern convenience and enduring performance.