Maintenance

When maintaining, do turn off the manual power switch.

Daily cleaning

Clean air conditioner and wire controller

Use soft cloth to dry clean

If there is too much dirt on the air conditioner panel, please soak the cloth with water, and then clean it. (The wire controller cannot use water to clean, it should use dry cloth to clean.)

It is forbidden to use gasoline, diluent, eradicator powder and chemical dishcloth etc. to clean, otherwise it may cause deformation and crack.

Maintenance after the using season

In a sunny day and FAN mode, let the unit operate about half a day to make the inner part of the unit dry.

Turn off the operation switch of the air conditioner, cut off the power switch. Otherwise, even the air conditioner is in OFF state, it will consume certain power.

Clean the air filer and the system of indoor unit, wash and clean the outdoor unit, and use dustcoat to cover the unit.

Maintenance before the using season

Check if there are any obstacles in the air inlet and outlet of indoor and outdoor unit to avoid the working efficiency drop.

Please do install the air filter and insure it is not dirty. Otherwise, the unit is damaged or has trouble due to the dust entry into the unit.

Please check first

In heating, in order to protect the compressor in starting the unit, please switch on the power switch of the unit 12 hours in advance before using it, and in using season, please always keep the power switch in ON state.

12

Image 13
Contents Free Combination Multi-split Type Room Air Conditioner Operation points Indoor unit Name of PartsPage Installation Safety Precautions Safety PrecautionsOperation safety precautions Cleaning, when Power firstAir conditioner Blow Art Simultaneously with a combustionOperation instruction Fan operation Then choose AUTO, COOLING, Dehumid IFYING, Heating operation Set of Timer mode Operation instruction Timer On/Off functionCancel Timer Set timeAfter turning on the unit Set the proper working mode Operation instruction Timer On-Off functionSet the Timer on time Press the time adjusting button Set the Timer OFF timeUse of Sleep function Operation instructionCOOLING, Dehumidifying operation Heating operationUsersí Attention Daily cleaning MaintenanceMaintenance after the using season Maintenance before the using seasonTrouble Contents Code Displayed TroubleshootingHaving peculiar smell in the out air When Troubles Occur Installation tools Installation instructionStandard accessories Accessories attached with the unit1Duct material Installation of DuctSafety precautions Installation procedure Install indoor unitIndoor unit Page Amplified Unit Figure Wood structure Install the hoisting screwOriginal cement panel Steel structureMaterial of connection pipe and thermal insulation Installation procedureInstall indoor unitConfirm drainage RequirementsMaterial and dimension of connecting pipe Permitted length and fall of connecting pipeConnection of refrigerant pipe Connection of pipe Installation procedure Connection of pipeAdditional charging amount of refrigerant Thermal insulation treatmentWiring method Wiring method of orbicular terminal Installation procedureWiring method of straight terminal Pressing method of connection wireInstallation procedure Install wire controller Cut and flaring method Other instructionTest run Set of the air sending of the fan motor

AE122BCAAA (H2EM-18H03) specifications

The Haier AE122BCAAA (H2EM-18H03) is a versatile and efficient air conditioning unit that stands out in the crowded market of HVAC systems. Designed to provide optimal cooling and heating solutions, this model is ideal for both residential and commercial spaces.

One of the main features of the Haier AE122BCAAA is its powerful cooling capacity. With an output of 18,000 BTUs, it effectively can cool large rooms, making it suitable for various applications such as living rooms, offices, or open spaces. This unit can also heat, making it a dual-function system that provides year-round comfort. The inverter technology embedded within this model ensures efficient energy usage, adapting to the cooling or heating load requirements in real time, thereby conserving energy and reducing utility bills.

The compact design of the Haier AE122BCAAA allows for easy installation and fit into different spaces without requiring extensive modifications. The unit features a sleek and modern aesthetic that blends seamlessly with various home or office interiors. Additionally, its low noise operation ensures a quiet environment, contributing to an undisturbed atmosphere.

Haier has equipped this model with advanced filtration technologies. The air filter captures dust and allergens, improving air quality significantly. Another advantageous feature is the dehumidification mode, which helps control moisture levels in the air, preventing mold growth and creating a more comfortable indoor environment.

The intuitive remote control allows users to manage settings conveniently, including temperature adjustments, fan speed, and mode selection. The programmable timer function enables users to set specific operating times, ensuring that the space is cool or warm precisely when needed.

Energy efficiency is another notable aspect of the Haier AE122BCAAA. It often comes with a high Seasonal Energy Efficiency Ratio (SEER), contributing to lower energy consumption. This feature is essential for environmentally conscious consumers looking to reduce their carbon footprint while still enjoying premium comfort.

In summary, the Haier AE122BCAAA (H2EM-18H03) is a robust and reliable air conditioning solution. With its powerful performance, advanced technologies, and user-friendly features, it offers an excellent choice for anyone in need of efficient cooling and heating. This model not only promises superior temperature management but also emphasizes energy efficiency and air quality, making it a top contender in the HVAC market.