Haier No. 0010572410 installation manual Installation Manual for Indoor Unit

Page 16

INSTALLATION MANUAL FOR INDOOR UNIT

1. Safety precautions

Please read these "Safety Precautions" first then accurately execute the installation work.

Though the precautionary points indicated herein are divided under two headings,

WARNING

 

and

CAUTION

, those points which are related to the strong possibility of an

installation done

in

error resulting in death or serious injury are listed in the

WARNING

section. However, there is

also a possibility of serious consequences in relationship to the points listed in the CAUTION section as well. In either case, important safety related information is indicated, so by all means,

properly observe all that is mentioned.

After completing the installation, along with confirming that no abnormalities were seen from the operation tests, please explain operating methods as well as maintenance methods to the user (customer) of this equipment, based on the owner's manual.

Moreover, ask the customer to keep this sheet together with the owner's manual.

WARNING

This system should be applied to places as office, restaurant, residence and the like. Application to inferior environment such as engineering shop could cause equipment malfunction.

Please entrust installation to either the company which sold you the equipment or to a professional contractor. Defects from improper installations can be the cause of water leakage, electric shocks and fires.

Execute the installation accurately, based on following the installation manual. Again, improper installations can result in water leakage, electric shocks and fires.

When a large air-conditioning system is installed to a small room, it is necessary to have a prior planned countermeasure for the rare case of a refrigerant leakage, to prevent the exceeding of threshold concentration. In regards to preparing this countermeasure, consult with the company from which you perchased the equipment, and make the installation accordingly. In the rare event that a refrigerant leakage and exceeding of threshold concentration does occur, there is the danger of a resultant oxygen deficiency accident.

For installation, confirm that the installation site can sufficiently support heavy weight. When strength is insufficient, injury can result from a falling of the unit.

Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes, etc. Improper installations can result in accidents due to a violent falling over of the unit.

For electrical work, please see that a licensed electrician executes the work while following the safety standards related to electrical equipment, and local regulations as well as the installation instructions, and that only exclusive use circuits are used.

Insufficient power source circuit capacity and defective installation execution can be the cause of electric shocks and fires.

Accurately connect wiring using the proper cable, and insure that the external force of the cable is not conducted to the terminal connection part, through properly securing it. Improper connection or securing can result in heat generation or fire.

Take care that wiring does not rise upward, and accurately install the lid/service panel. Its improper installation can also result in heat generation or fire.

When setting up or moving the location of the air conditioner, do not mix air etc. or anything other than the designated refrigerant (R407C) within the refrigeration cycle.

Rupture and injury caused by abnormal high pressure can result from such mixing.

Always use accessory parts and authorized parts for installation construction. Using parts not authorized by this company can result in water leakage, electric shock, fire and refrigerant leakage.

CAUTION

Execute proper grounding. Do not connect the ground wire to a gas pipe, water pipe, lightning rod or a telephone ground wire. Improper placement of ground wires can result in electric shock.

The installation of an earth leakage breaker is necessary depending on the established location of the unit. Not installing an earth leakage breaker may result in electric shock.

Do not install the unit where there is a concern about leakage of combustible gas.

The rare event of leaked gas collecting around the unit could result in an outbreak of fire.

For the drain pipe, follow the installation manual to insure that it allows proper drainage and thermally insulate it to prevent condensation. Inadequate plumbing can result in water leakage and water damage to interior items.

15

Image 16
Contents Duct Type AIR Conditioning Table of Contents Disposal of the old air conditioner Safety Precautions Make sure the system is groundedDo not operate the system while Applicable ambient temperature range Machine is adaptive in following situationParts and Functions Malfunction Unit fails to startCooling or heating is not sufficient Cooling is not sufficientFollowings are not malfunction Shuru ShuruCare and Maintenance Points to observeWhen heating is started HOT KEEPis operated in the following casesInstallation Manual for Outdoor Unit Installation placeInstallation Installation where the area with strong windsOpen space requirement around the unit Precautions for refrigerant piping Outline pipingPiping size Piping connectionPurging method the refrigerant is R407C To use vacuum pumpInstallation Manual for Indoor Unit Avoid installation and use at those places listed below Preparation of indoor unitFigure of installation dimension unit mm Preparation for suspending the unitUse embedded parts and foot screw, etc to mount Original cement panel Connection pipe Liquid side Installation Manual for Electric Wiring Electric wiring

No. 0010572410 specifications

Haier No. 0010572410 is a state-of-the-art home appliance that embodies the brand's commitment to innovation, quality, and customer satisfaction. This model has garnered attention in the market for its advanced features and cutting-edge technologies designed to enhance user experience and efficiency.

One of the standout characteristics of Haier No. 0010572410 is its energy efficiency. Equipped with the latest energy-saving technology, this appliance reduces energy consumption without compromising performance. This feature not only contributes to lower electricity bills but also aligns with environmentally friendly practices, helping users reduce their carbon footprint.

The appliance boasts an impressive capacity, making it suitable for both small and large households. Its spacious design allows for better organization and storage, accommodating various types of items with ease. Whether it's used in a kitchen for food storage or in a laundry room for clothing, Haier No. 0010572410 ensures that users can make the most of the available space.

In terms of technology, the model incorporates smart features that allow for remote operation and monitoring. Users can control and manage their appliance through a smartphone app, providing convenience and flexibility. This technology enables users to set schedules, receive notifications, and even troubleshoot issues without the need for physical interaction with the appliance.

Safety is a top priority for Haier, and No. 0010572410 reflects this commitment. The appliance is equipped with multiple safety features, including automatic shut-off capabilities and child lock functions. These features ensure that users can operate the appliance safely and securely, making it a reliable choice for families.

Another key feature of Haier No. 0010572410 is its user-friendly interface. The intuitive controls and clear display make it easy for anyone to operate, regardless of tech-savviness. This focus on user experience allows individuals of all ages to take full advantage of the appliance's capabilities.

Overall, Haier No. 0010572410 represents a blend of efficiency, safety, and advanced technology, making it a top contender in its category. Whether for everyday use or special occasions, this appliance meets the diverse needs of modern households, setting a benchmark for quality and performance in the industry.