Haier HSU-0912RF03 Power Source Installation, Cutting and Flaring Work of Piping, On Drainage

Page 8

1.Power Source Installation

The power source must be exclusively used for air conditioner. (Over I0A)

In the case of installing an air conditioner in a moist place, please install an earth leakage breaker.

For installation in other places, use a circuit breaker as far as possible.

2.Cutting and Flaring Work of Piping

Pipe cutting is carried out with a pipe cutter and burs must be removed. After inserting the flare nut, flaring work is carried out.

A

1.Cut pipe

Flare tooling die

2.Remove burs

 

Flare tool for R410A

Conventional flare tool

 

Clutch-type

clutch-type(Rigid-type)

Wing-nut type (Imperial-type)

 

 

 

 

 

0~0.5mm

1.0~1.5mm

1.5~2.0mm

 

 

 

 

3.Insert the flare nut

4.Flare pipe

3.On Drainage

Correct

 

Incorrect

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lean Damage of flareCrack Partial Too outside

Please install the drain hose so as to be downward slope without fail. Please don't do the drainage as shown below.

 

 

 

Less than 5cm

It becomes high

The end is immersed

It waves.

The gap with the ground

There is the bad smell

midway.

in water.

 

is too small

from a ditch

Please pour water in the drain pan of the indoor unit, and confirm that drainage is carried out surely to outdoor.

In case that the attached drain hose is in a room, please apply heat insulation to it without fail.

Check for Installation and Test Run

Please kindly explain to our customers how to operate through the instruction manual.

Check Items for Test Run

Put check mark in boxes

Gas leak from pipe connecting?

Heat insulation of pipe connecting?

Are the connecting wirings of indoor and outdoor firmly inserted to the terminal block?

Is the connecting wiring of indoor and outdoor firmly fixed?

Is drainage securely carried out?

Is the lamp normally lighting?

Is the earth line securely

Are cooling and heating (when

connected?

in heat pump) performed normally?

Is the indoor unit securely fixed?

Is the operation of room temperature

Is power source voltage abided

regulator normal?

by the code?

 

Is there any noise?

 

8

Image 8
Contents Installation Manual of Room Air Conditioner Power Source When the mounting plate is fixed side bar and lintel Making a Hole on the Wall and Fitting the Piping Hole CoverInstallation of the Indoor Unit Drawing of pipe Fixing the indoor unit bodyWhen connecting the cable after installing the indoor unit When connecting the cable before installing the indoor unitInstallation of Outdoor Unit Connection of pipesConnection Attaching Drain-ElbowPurging MethodTo use vacuum pump Power Source Installation Check for Installation and Test RunCutting and Flaring Work of Piping On DrainageFR Conformité AUX Directives Européennes Pour LES Modèles IT Conformità Alle Direttive Europee PER I ModelliEN European Regulations Conformity for the Models ES Conformidad Europea DE LAS Regulaciones Para LOS Modelos Requisitos Para LA EliminaciónFR Information Importante Relative AU Réfrigérant Utilisé IT Informazioni Importanti SUL Refrigerante UtilizzatoEN Important Information Regarding the Refrigerant Used GWP = Potencial de calentamiento global

001051, HSU-0912RF03 specifications

The Haier HSU-0912RF03,001051 is a notable air conditioning unit that combines efficiency, reliability, and cutting-edge technology, making it an excellent choice for residential and small commercial spaces. Designed to provide optimal cooling and heating performance, this model has gained popularity for its user-friendly features and robust design.

One of the standout features of the Haier HSU-0912RF03,001051 is its energy efficiency. With a high Seasonal Energy Efficiency Ratio (SEER), this unit ensures significant energy savings while maintaining a comfortable indoor climate. This efficient operation not only reduces electricity bills but also lessens the environmental impact, an essential consideration in today's eco-conscious world.

In addition to energy efficiency, the Haier HSU-0912RF03,001051 is equipped with a powerful cooling and heating capacity. It effectively regulates indoor temperatures, providing reliable performance during extreme weather conditions. The unit showcases a sleek design, allowing it to seamlessly blend into various interior settings while also needing minimal maintenance.

Furthermore, this model employs advanced inverter technology, which enables the compressor to adjust its speed according to the cooling or heating demand. This not only ensures a consistent temperature but also enhances energy savings by operating at lower capacities when needed. The inverter system significantly reduces noise levels, making it ideal for bedrooms, living rooms, or office spaces where a quiet environment is preferred.

The Haier HSU-0912RF03,001051 also features smart technology capabilities, such as Wi-Fi connectivity, allowing users to control the unit remotely via a smartphone app. This innovative feature enhances user convenience, enabling adjustments to be made from anywhere, whether you're home or away.

Further enhancing user experience, the air conditioner comes with an easy-to-use remote control, comprehensive airflow settings, and a programmable timer, adding convenience and flexibility to its operation.

In conclusion, the Haier HSU-0912RF03,001051 air conditioning unit is an outstanding choice for anyone seeking a reliable, efficient, and advanced climate control solution. With its blend of energy efficiency, powerful performance, and smart features, it guarantees a comfortable living environment with minimal environmental impact. This unit is sure to exceed expectations and deliver comfort season after season.