Haier HSU-18CV03(T3), HSU-24CV03(T3) Removal of the restriction of emergency or test operation

Page 20

Operation

Emergency and Test Operation

Emergency operation:

Use this operation only when the remote controller is defective or lost.

When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation.

In this operation, the system automatically selects the operation modes, cooling or heating, according to the room temperature.

Temperature

Operation

Designated

Timer

Air flow

 

mode

temperature

mode

 

ABOVE 23OC

COOLING

26OC

NO

AUTOMATIC

BELOW 23OC

HEATING

23OC

NO

AUTOMATIC

It is not possible to operate in dry mode.

Test operation:

Test operation switch is the same as emergency switch.

Use this switch in the test operation when the room temperature is below 16OC, do not use it in the normal operation.

Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi".

After 30 minutes, test operation ends automatically.

Removal of the restriction of emergency or test operation

Press the emergency operation switch once more, or manipulate through the remote controller; the "Pi" sound, the emergency or test operation is terminated.

When the remote controller is manipulated, it gets the system back to the normal operation mode.

19

Image 20
Contents HSU-18CV03T3 HSU-24CV03T3 No.0010556977Contain no fluorochloric hydrocarbon Disposal of the packaging of yourNew air conditioner Situation SpecificationsMachine is adaptive in following Safety Instruction Check proper installation of the drainage securelyOFF Strict Enforcement Indoor unit Outdoor unitCode Parts and Functions Remote controller OperationAuto Operation Cool Operation Dry Operation Fan Operation About FAN operationHeat Operation Air Flow Direction Adjustment Status display of air sendingUp and down air flow direction Left and right air flow directionSleep Operation Timer On/Off Operation Time settingConfirming your setting Cancel Timer modeTimer On-Off Operation Setting of health airflow function Cancel of the health airflow functionHealth airflow Operation Press ON/OFF to startingIt is not possible to operate in dry mode Removal of the restriction of emergency or test operationSetting of proper room Temperature Or outletAir Filter cleaning Remote ControllerDo not use the following for cleaning Open the lnlet Grille Detach the standard air filterAttach new Air Purifying Filter Attach the standard air filterOperate in cooling mode for 2-3 hours To Keep Your Air conditioner in Good Condition after SeasonCleaning the standard air filter Connecting the earthing cableDo not block the air inlet or outlet Plug-in Incomplete earthing may cause an electric shockTrouble shooting Before asking for service, check the following first

HSU-24CV03(T3), HSU-18CV03(T3) specifications

The Haier HSU-18CV03(T3) and HSU-24CV03(T3) are modern air conditioning units designed to provide efficient cooling for residential and commercial spaces. Both models are part of Haier's commitment to combining innovative technology with user-friendly features to enhance comfort and energy efficiency.

One of the standout features of these units is their inverter technology, which allows for variable speed compressor operation. This means that the air conditioning system can adjust its cooling output based on the indoor temperature, leading to significant energy savings. By avoiding the constant on-off cycling seen in traditional units, the HSU-18CV03(T3) and HSU-24CV03(T3) maintain a more stable room temperature while consuming less electricity.

Both models are equipped with advanced air filtration systems that help improve indoor air quality. These filters are designed to capture dust, allergens, and other particulate matter, ensuring that the air you breathe is clean and healthy. The easy-to-clean filter design also simplifies maintenance, making it convenient for users to keep their units operating at peak performance.

The cooling capacity of the HSU-18CV03(T3) is 1.5 tons, while the HSU-24CV03(T3) offers a cooling capacity of 2 tons. This makes the former ideal for smaller rooms, while the latter is suitable for larger spaces. Additionally, both units feature a sleek, modern design that blends seamlessly into various interior styles, making them aesthetically pleasing additions to any room.

Energy efficiency is further exemplified by the high EER (Energy Efficiency Ratio) ratings of these units, ensuring that users benefit from lower energy bills without sacrificing comfort. The quiet operation of the HSU-18CV03(T3) and HSU-24CV03(T3) is another significant advantage, allowing users to enjoy their air conditioning without disruptive noise.

Furthermore, these models come with multiple modes of operation, including cooling, heating, and dehumidification, allowing flexibility for different weather conditions. The user-friendly remote control and digital display make it easy to adjust settings from anywhere in the room.

Overall, the Haier HSU-18CV03(T3) and HSU-24CV03(T3) are exemplary air conditioning solutions, merging efficiency, comfort, and advanced technology to meet the diverse needs of users. Whether in a home or an office, these units stand out for their performance, reliability, and innovative features.