Haier HW-05LMA13 Selection of the Installation Position, Enclosed Accessories of the Conditioner

Page 2

4 AIR CONDITIONER INSTALLATION(ONLY FOR REFERENCE)

SELECTION OF THE INSTALLATION POSITION

5 TROUBLESHOOTING

Before calling for service.

Check the following points before calling for repairs or service.

1,The air-conditioner is better installed in shadow or in a place with short period of sunshine. In case the air-conditioner is installed at the point exposed directly to the sunshine, it should be protected from the direct sunlight as possible in order to avoid the long time of direct sunlight otherwise its performance will be lowered. (As illustrated in Fig. 1).

2.For the convenience of operation, it is recommended that air-conditioner be installed at least at the height of 760-1300 mm above the floor and no obstacles before it for a free airflow.

3.The shutters at both sides and the top of

 

air-conditioner should be protruded outdoors free

 

from being blocked by wall, window,ect.

 

4.The back of air-conditioner should be kept over

 

500mm from the obstacles (for example, wall,

 

etc.) (As illustrated in Fig. 2).

 

5.To have an efficient drainage, the back part of

 

the air-conditioner should be inclined downward

>500mm

by 5-10mm (As illustrated in Fig. 3).

 

cover

support

fig.1

5-10mm

 

Phenomenon

Cause or check points

Solution

 

 

 

 

 

 

 

Switch on the machine but it

If the machine is started after stop,it will need about 3 minutes

 

 

does not work immediately.

to re-start so as to prevent the fuse from break.

 

 

 

 

 

 

 

Switch on the machine but it

 

 

 

 

does not work.

Is plug firmly inserted?

Readjust power supply

 

 

 

 

 

 

Is there power failure?

 

 

 

 

 

 

 

 

 

Does fuse get burned?

Replace fuse.

 

fig.2fig.3

NOTES:

For longer and trouble-free operation of the unit, pay special attention to the following:

Install air-con at a place strong enough to support the unit.

Leave enough space around air inlet and outlet for better circulation.

Avoid places where flammable gas leaks.

Problems may occur if unit is installed in the following places: Place where oil exists in the air including engine oil or seaside with salt breeze blows and hot spring area with sulphurous gas in the air.

THE ENCLOSED ACCESSORIES OF THE CONDITIONER

Name

Manual

Figure

Is thermostat switch

Readjust the thermostat.

wrongly adjusted?

 

Is there any direct

Use curtain or blind.

 

sunlight in the room?

 

The cooling effect is not good.

 

Are doors or windows

Shut doors and windows.

left open?

 

Are there any obstacles

Remove the obstacles.

blocking air inlet and

 

outlet?

 

Is air filter clogged?

Clean it.

 

Is there too much heat

Remove the heat source

source in the room?

PREPARATIONS BEFORE INSTALLATION

Make the wall hole or window hole (see Fig.1)

MODEL

A

B

Iron frame

A

 

 

 

HW-05LMA13

334mm

440mm

 

Width of the wall

Prepare unit for installation:

Fig. 1

 

Take out the conditioner and accessories from the package .

57

68

If problems can not be solved please pull out power plug and contact your dealer.

INSTALLATION PROCEDURES

1.Fix the prefabricated iron frame to stable position by expansible screws.

2.Put the whole machine with all the accessories installed on the iron frame.

3.Fill any distance between the wall hole and the machine body with flexible sponge rubber strip to prevent the entering of outer noise and the leaking of the coolness.

4.After installation of the conditioner, insert the power plug into the outlet and perform test-run.

Cautions

Power cord: Be sure to use the exclusive power cord.

Change installation place: If air-con need to be changed to another place please contact the dealer, who sold you the unit.

Always use at the rated voltage and with specfic air conditioning circuit