9. Delay Time Setting

Delay function means that, system automatically calculates the time needed to reach temperature setting value with a defaulted 2150 W power, then determines the time to

start heating, and automatically heats to the set temperature before the preset delayed time to use hot water. Two Delay Times (Time 1 + Time 2) means machine as needed can heat water in two delayed use times. This machine can be manually set two delayed water use times. Setting will take PC clock time as reference. Defaulted Time 1 use time is 17:00 and Time 2 use time is 06:00. In Delay mode, system default heating power 2150 W can't be adjusted.

Example: as shown in Fig. 12, set delayed use Time 1 at 10:30.

With machine powered on, consecutively press Mode button until it enters Time 1

operation status with delay indication and symbol

lighted. Press Set button to enter

Time 1 hour setting status with Time 1 hour digits flashing. Press

or

button to get

10:00. While hour digits are flashing, you can press Set button to confirm and enter Time 1 minute setting. Adjust the value to 10:30 with or button.

Then you may press Set button to confirm current settings or wait 6 s after which machine automatically confirms and quits. Time 2 time setting is similar to Time 1, i.e. press Mode button to enter Time 2 operation mode and set Time 2 time with Set button.

Note: If large quantity hot water is used after delay mode is started and water heaters starts heating, resulting in water heater still hasn't reached temperature setting at delayed use time, machine will automatically extend heating for half an hour and stops. If actual temperature has reached setting value before delayed use time, and it decreases by 5 before reaching delayed use time, machine will calculate heating time again and determines if re-heating is needed or not. Likewise, if water heater hasn't reached set temperature at delayed use time due to too low supply voltage, machine also automatically extends for half an hour and stops.

10.Operation Mode Selection

After powering on, by consecutively pressing Mode button, system will shift between Real-time Heat / Warm (with Real-time indication), Medium Warm (with Medium Warm indication), Night Power (with Night Power indication), Time 1 (with Delay and

indication), Time 2 (with Delay and indication) ,Time 1 + Time 2 (with Delay and ,

indication) and Intelligent (with Intelligent indication) modes. User can select any mode as current operation mode. Only after being selected as current operation mode, corresponding settings can be executed.

Example: clock at 7:00, heating power of 2150 W, temperature setting of 75(temperature setting and actual temperature flash alternatively), delayed useTime 1 being set at 10:00. If you want to use water at 10:00, after settings are made, you must press Mode button to adjust current mode as Time 1 mode. Machine will automatically heats water to set temperature at 10:00. Otherwise (e.g. in Night Power mode as shown in Fig. 13), it doesn't execute Time 1 function. You need to select Delay and symbol with Mode button, and then Time 1 function can be executed.

11. Powering Off

After taking shower, you can lightly press On/Off button to power off the machine. Hints:

A.With machine powered on, you can press Set button to set On/Off time for various modes, and adjust time with or button. In Real-time Heat mode, you can press Set button to adjust clock hour and minute values. In Delay mode, you can press Set button to set delayed use time. In Medium Warm and Intelligent mode, Set button is inactive.

B.The machine has multiple safety means like current leakage protection, over- temperature protection, sensor short-circuit and open-circuit protection, which can realize full disconnection and display fault code. All fault protections are unrecoverable protection which needs local after-sales service.

C.This water heater has power failure memory function. You needn't re-set heating power level, heating temperature ,clock and operation mode. Machine will directly go to previous working status after powering on again.

Safety Precautions

 

The water heater shall use 230 V~ / 50 Hz

Check if power meter and wire size are consistent

power supply from a separate socket (no

with water heater rated current. If necessary, ask

multi - purpose socket) and be reliably

experienced qualified electricians to check.

grounded. Power plug pins shall be cleaned

 

in time to avoid any contamination causing

 

accidents like fire.

 

 

 

 

 

 

 

 

 

 

 

У

¡

 

 

 

 

 

 

 

 

л

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

²

 

 

 

 

 

 

Do not use damaged wire, socket or appliances

Power socket for water heater shall be

with loose plug, otherwise accidents like

located in a dry place free of water spray. Do

electric shock, short circuit and fire may occur.

not insert or pull the power plug with wet

Make sure power plug closely fits with power

hands, for accidents like electric shock or

socket.

injury may happen.

 

 

 

 

 

 

 

 

¡

¡

 

 

 

 

 

²

 

 

 

Ô´

 

 

²

 

 

 

»¿

 

 

 

ÏÚÔ´

 

 

¿»

 

 

 

 

 

ÃÓÏÚ

 

 

 

ÒÉ

 

ÉÒ

 

 

¢¼

Ó´ÓÃ

 

 

 

 

Ô

Ô

 

Á

Ó´

 

 

 

 

 

 

¼¢

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Á

 

 

 

 

 

 

 

 

 

For first use after installation, the tank must be

 

 

 

 

 

 

 

 

 

 

full of water before connecting the power.

Please do not point the showerhead towards

Otherwise, heating element overheat may

human body when turning on or off the faucet,

cause troubles.Children taking shower must be

avoiding to be scalded by a small stream of

attended by adults.

hot water.

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

In winter in cold regions, for long-term out-of-

Damaged power cord must be replaced by

after-service technicians with special cable

use, please lift the safety valve handle to empty

(factory provided). Other persons shall not

the water, avoiding ice formation damaging the

dismantle or repair. In addition, do not place

water heater.

flammable matters nearby the water heater.

Temperature value indicated on the display is for water around the detection point. Outlet water temperature is generally higher. Before use, please first turn on cold water and then adjust water temperature as you need. During use, the displayed value is still water temperature at detection point instead of outlet temperature. Please do not directly turn on hot water.

The product adopts Haier Safe Care patented technology. In normal installation, even in severe case that ground wire is live due to wrong connection, the product Safe Care technology can filter and efficiently ensure your safety. However, whenever your feel a sensory current, please pull out the power plug and notify local after-service men in time. Do not dismantle by yourself.

Description of the Symbols

Never do that

Be sure to act as per instructions

Image 5
Contents Silver Sea-ox Packing List Pre-safe Expert Cleaning and MaintenanceContents Electric Circuit Diagram Before Usage Use of Remote ControllerFeatures Special RemindingViews and parts Operation DiagramOperation Instructions Never do that Be sure to act as per instructions Safety PrecautionsOperation Instructions Power 850 W /1300 W /2150 W Setting EnvironmentParameters ² »Ò ª ²× Ó ÎÚ Þ· Ũ ÅË µ µÄ Ø· ½Dimensions Remote Controller Panel Illustration InstallationDelay Indication Time 1 Indication Control Panel Illustration

FCD-HTHMG50-III(E), FCD-HTHMG60-III(E), FCD-HTHMG80-III(E), FCD-HTHMG100-III(E) specifications

Haier, a globally recognized leader in home appliances, has continued to innovate with its FCD-HTHMG series, which includes the FCD-HTHMG50-III(E), FCD-HTHMG60-III(E), FCD-HTHMG80-III(E), and FCD-HTHMG100-III(E) models. Designed to meet the diverse needs of consumers, these high-capacity water heaters feature a range of advanced technologies and characteristics that prioritize efficiency, performance, and user convenience.

One of the standout features of the FCD-HTHMG series is its high energy efficiency. These models are equipped with intelligent temperature control that optimizes power consumption, ensuring minimal energy wastage while maintaining precise heating. This not only helps in reducing electricity bills but also contributes to a greener environment.

The series boasts a robust build with corrosion-resistant materials, ensuring longevity and durability. The internal tank is designed to withstand high pressures and temperatures, providing reliable hot water supply for various household needs. Whether it’s for showers, washing dishes, or laundry, these water heaters can efficiently supply hot water on demand.

The FCD-HTHMG collection also integrates smart connectivity features. With Wi-Fi capability, users can control the heater remotely via a mobile app. This enables them to adjust settings, schedule heating times, and monitor energy usage—all from the convenience of their smartphones. Such smart functionality enhances user convenience and allows for tailored usage that fits individual lifestyles.

In addition to their practicality, these models are designed with sleek aesthetics, making them a seamless addition to modern households. The user-friendly interface and LED display allow for easy operation, making it accessible for all family members.

Safety is paramount in the FCD-HTHMG series, featuring multiple protection mechanisms including anti-dry protection, temperature control, and pressure relief systems. This ensures peace of mind for users while using the appliance.

In conclusion, the Haier FCD-HTHMG50-III(E), FCD-HTHMG60-III(E), FCD-HTHMG80-III(E), and FCD-HTHMG100-III(E) models exemplify cutting-edge technology and thoughtful design, making them exceptional choices for anyone in need of reliable and efficient water heating solutions. With a commitment to quality and user satisfaction, Haier continues to set the standard in the home appliances market.