CMS801 DC
Architectural Specifications
The Ceiling Monitor System shall consist of a 200mm (8.00") full range, point source, constant directivity Dual ConcentricTM transducer and passive frequency dividing network mounted in a vented, injection moulded, paintable front baffle in
The back can in both PI
For
Performance of the Ceiling Monitor System shall meet or exceed the following criteria: The system shall have a conical coverage pattern of 100 degrees (1kHz to 6kHz). Frequency response measured on axis shall be 40 Hz - 35kHz
The Ceiling Monitor System shall be equipped with a 60W high performance line transformer for use in 70.7 or 100 Volt distributed audio systems with 60, 30, 15, 7.5* Watt taps available. An easily accessible rotary switch located on the front baffle shall be available for selecting transformer and low impedance settings. A weather resistant perforated steel grille covers the transducer and switch.
Two support rails and one
Bezel diameter 325mm (12.80")
BM Front of ceiling to rear of back can 310.50mm (12.22"), Front of ceiling to top of safety loop 327.80mm (12.90")
PI Front of ceiling surface to rear of speaker unit 118.70mm (4.67"), Front of accessory back can bezel to top of safety loop 168.50mm (6.63")
The Ceiling Monitor System shall be the...CMS801 DC.
*70 Volt only
anfragen@tannoy.com |
|