Troubleshooting
Troubleshooting
Problem | Cause | Solution |
|
|
|
|
|
|
Motor runs but pump will not prime. | Motor rotation wrong. (12 VDC units | Check wiring instructions for possible |
| only.) | problems. |
|
|
|
| Missing relief valve | Remove gear cover (1b) inspect seal |
|
| (4c), replace if missing or damaged. |
|
|
|
| Sheared drive key (1g). | Remove cover (1b) and inspect key |
|
| (1g/10b), replace if worn or sheared. |
|
|
|
| Dirt under relief poppet (4a) or seal | Remove cover (1b) and inspect, |
| (4c). | clean or replace if damaged. |
|
|
|
| Strainer seal (3d) leaking. | Inspect and replace if damaged. |
|
|
|
| Suction height too high to prime. | See Priming Pump, page 5. |
|
|
|
| Worn or damaged gears. | Remove cover (1b) and inspect |
|
| gears. Replace if worn or damaged. |
|
|
|
| Fluid level low. | Refill tank. |
|
|
|
| Cover seal (1f/10c) damaged. | Replace if worn or damaged. |
|
|
|
| Inlet strainer (3b) clogged. | Remove and clean or replace. |
|
|
|
| Air leak in suction tube. | Inspect all joints in suction tube, |
|
| make sure all joints have sealant |
|
| applied. |
|
|
|
| Air lock in system. | This may occur if filter or meter or |
|
| automatic |
|
| this occurs, fill pump and meter with |
|
| herbicide through top of pump. |
|
|
|
| Motor does not run at proper speed. | Check electric connections. Check |
|
| supply voltage for proper voltage |
|
| level. |
|
|
|
Unit pumps but output flow is low. | Clogged inlet strainer (3b). | Clean or replace. |
|
|
|
| Air leak in suction tube. | Check to make sure all joints in suc- |
|
| tion tube are sealed. |
|
|
|
| Suction tube too close to tank | Suction tube must have a 2 in. |
| bottom. | (51 mm) minimum clearance. |
|
|
|
| Tank empty. | Refill tank. |
|
|
|
| Tank not vented. | Tank must be vented to atmosphere. |
|
|
|
| Worn or damaged gears. | Remove cover (1b) and inspect |
|
| gears. Replace if worn or damaged. |
|
|
|
| Damaged motor. | Replace motor. |
|
|
|
| Clogged suction tube, hose, or | Inspect and clean. |
| nozzle. |
|
|
|
|
Motor stalls when nozzle is closed. | Bypass relief valve (4a) stuck. | Inspect relief valve, making sure |
|
| poppet is free. Replace if damaged. |
|
|
|
| Low supply voltage. | Check supply voltage. |
|
|
|
| Gears (1c/10a) damaged and | Inspect gears. Gears should turn |
| binding. | freely. Replace if damaged. |
|
|
|
| Faulty motor. | Replace motor. |
|
|
|
8 | 311628C |