Goodman Mfg RT6332013r1 service manual GPH1324-60M41, HKR Electrical Data

Page 6

PRODUCT DESIGN

 

 

GPH13[24-60]M41*

HKR ELECTRICAL DATA

 

 

 

 

 

 

 

 

 

 

 

 

Circuit #1

Circuit #2

 

 

 

Minimum Circuit

Maximum

Minimum Circuit

Maximum

Actual

 

Overcurrent

Overcurrent

kW & BTU

 

Ampacity

Ampacity

 

Protection (amps)

Protection (amps)

at 240V

 

at 208 / 240V

at 208 / 240V

 

at 208 / 240V

at 208 / 240V

 

 

 

 

 

 

 

GPH1324M41*

 

 

 

 

 

 

HKR05A,CA

24 / 27

30 / 30

----

----

4.75 / 16,200

HKR08A,CA

33 / 28

40 / 40

----

----

7.00 / 23,800

HKR10A,CA

45 / 51

60 / 60

----

----

9.50 / 32,400

GPH1330M41*

 

 

 

 

 

 

HKR05A,CA

24 / 27

30 / 30

--

--

4.75 / 16,200

HKR08A,CA

34 / 39

40 / 40

--

--

7.0 /

23,800

HKR10A,CA

45 / 52

60 / 60

--

--

9.5 /

32,400

HKR15A,CA

45 / 52

60 / 60

22 / 25

30 / 30

14.25

/ 48,600

GPH1336M41*

 

 

 

 

 

 

HKR05A,CA

24 / 27

30 / 30

----

----

4.75 / 16,200

HKR08A,CA

34 / 39

40 / 40

----

----

7.00 / 23,800

HKR10A,CA

45 / 52

60 / 60

----

----

9.50 / 32,400

HKR15A,CA

45 / 52

60 / 60

22 / 25

30 / 30

14.25

/ 48,600

GPH1342M41*

 

 

 

 

 

 

HKR05A,CA

24 / 27

30 / 30

--

--

4.75 / 16,200

HKR08A,CA

34 / 39

40 / 40

--

--

7.0 /

23,800

HKR10A,CA

45 / 52

60 / 60

--

--

9.5 /

32,400

HKR15A,CA

45 / 52

60 / 60

22 / 25

30 / 30

14.25

/ 48,600

GPH1348M41*

 

 

 

 

 

 

HKR05A,CA

25 / 28

30 / 30

----

----

4.75 / 16,200

HKR08A,CA

34 / 40

40 / 40

----

----

7.00 / 23,800

HKR10A,CA

46 / 53

60 / 60

----

----

9.50 / 32,400

HKR15A,CA

46 / 52

60 / 60

22 / 25

30 / 30

14.25

/ 48,600

HKR20A,CA

46 / 52

60 / 60

43 / 49

60 / 60

19.50

/ 66,500

GPH1360M41*

 

 

 

 

 

 

HKR05A,CA

26 / 30

30 / 30

----

----

4.75 / 16,200

HKR08A,CA

36 / 40

40 / 40

----

----

7.00 / 23,800

HKR10A,CA

48 / 54

60 / 60

----

----

9.50 / 32,400

HKR15A,CA

48 / 54

60 / 60

22 / 25

30 / 30

14.25

/ 48,600

HKR20A,CA

48 / 54

60 / 60

43 / 49

60 / 60

19.50

/ 66,500

IMPORTANT NOTE: A separate power supply is required for the HKR heater kit.

Heating kW Correction Factor

Supply Votage

240

230

220

210

208

 

 

 

 

 

 

Correction Factor

1.0

0.93

0.85

0.78

0.76

 

 

 

 

 

 

Multiply rated kW by correction factor to get actual kW

All wires and overcurrent protection devices are sized for use with electric heaters only and without WARNING refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE UNIT SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent pro-

tection during refrigeration cycle.

6

Image 6
Contents Technical Manual Product Identification Goodman will not be responsibleFor any injury or property damage Do not connect or use any device Product Design Rooftop Installation -Multi-positional M GPH1324-60M41 HKR Electrical DataProduct Dimensions GPH1324-60M41Package Heat Pump Specifications GPH1324-36M41AB InformationPackage Heat Pump Specifications GPH1342-60M41AB Accessories Accessories GPC/GPH****M ModelsBlower Performance Data Model Speed Volts P In. of H2OPerformance Data FormulasCooling Performance Data GPH1324M4110.3 10.2 10.4 10.8 GPH1330M41 11.9 GPH1336M41 28.7 GPH1342M41 16.7 17.1 17.7 GPH1348M41 1933HI PR GPH1360M41 20.1 19.9 20.3 Heating Performance Data GPH1348-60M41 Wiring Diagrams GPH1324-42M41ABGPH1348-60M41AB