Haier HR18D2VAR, HR36D2VAR, HR30D2VAR, HR24D2VAR manual Message to Owner

Page 2

! WARNING

These instructions are intended as an aid to qualified, licensed service personnel for proper installation, adjustment and operation of this unit. Read these instructions thoroughly before attempting installation or operation. Failure to follow these instructions may result in improper installation, adjustment, service or maintenance possibly resulting in fire, electrical shock, property damage, personal injury or death.

This product is designed and manufactured to permit installation in accordance with National Codes. It is the installer's responsibility to install the product in accordance with National Codes and/or prevailing local codes and regulations. The manufacturer assumes no responsibility for equipment installed in violation of any codes or regulations.

The United States Environmental Protection Agency (EPA) has issued various regulations regarding the introduction and disposal of refrigerants in this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. Because these regulations may vary due to the passage of new laws we suggest that any work on this unit be done by a certified technician. Should you have any questions please contact the local EPA office.

The manufacturer's warranty does not cover any damage or defect to the air conditioner caused by the attachment or use of any components, accessories or devices (other than those authorized by the manufacturer) into, onto, or in conjunction with the air conditioner. You should be aware that the use of unauthorized components, accessories or devices may adversely affect the operation of the air conditioner and may also endanger life and property. The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized components, accessories or devices.

Attach the service panel to the outdoor unit securely. If the service panel is not attached securely, it could result in a fire or an electric shock due to dust, water, etc.

These instructions are intended as an aid to qualified, licensed service personnel for proper installation, adjustment and operation of this unit. Read these instructions thoroughly before attempting installation or operation. Failure to follow these instructions may result in improper installation, adjustment, service or maintenance possibly resulting in fire, electrical shock, property damage, personal injury or death.

This product is designed and manufactured to permit installation in accordance with National Codes. It is the installer's responsibility to install the product in accordance with National Codes and/or prevailing local codes and regulations. The manufacturer assumes no responsibility for equipment installed in violation of any codes or regulations.

The following information should be read carefully prior to installing units with scroll compressors.

1.PUMP DOWN PROCEDURE

CAUTION: Scroll compressors should never be used to evacuate the air conditioning system. Vacuums this low can cause internal electrical arcing resulting in a damaged or failed compressor.

2.CRANKCASE HEATER

Scroll equipped units do not have or do not require a crankcase heater.

3.TIME DELAY COMPONENT

The time delay is located in the low voltage control circuit. When the compressor shuts off due to thermostat operation or a power failure, this components keeps the compressor off for at least 30 seconds which allows the system pressure to equalize.

4.UNBRAZING SYSTEM COMPONENTS

If the refrigerant charge is removed from a scroll equipped unit by bleeding the high side only, it is sometimes possible for the scrolls to seal, preventing pressure equalization through the compressor. This may leave the low side shell and suction line tubing pressurized. If a brazing torch is then applied to the low side while the low side shell and suction line contains pressure, the pressurized refrigerant and oil mixture could ignite when it escapes and contacts the brazing flame. To prevent this occurrence, it is important to check both the high and low side with manifold gauge before unbrazing, or in the case of repairing a unit on an assembly line, bleed refrigerant from both the high and low side.

Message to Owner

These instructions should be carefully read and kept near the product for future reference. While the instructions are addressed primarily to the installer, useful maintenance information is included. Have your installer acquaint you with the operating characteristics of the product and periodic maintenance requirements.

Image 2
Contents HR18D2VAR HR24D2VAR HR30D2VAR HR36D2VAR Message to Owner Introduction Nomenclature for Model Number18383 System Capacity Cooling Equipment Protection from Environment InstallationUnit Inspection Unit Clearances Line Insulation Refrigerant Line Length Ft Unit Size Ton Refrigerant Metering Devices Evacuation Page System Startup Operation MiscellaneousSymptom Possible Cause Remedy HR18-36D2VAR Made in P.R.C

HR24D2VAR, HR36D2VAR, HR18D2VAR, HR30D2VAR specifications

Haier, a globally recognized brand in home appliances, has developed a line of air conditioning units that includes the HR30D2VAR, HR18D2VAR, HR36D2VAR, and HR24D2VAR models. These units are designed to deliver optimal comfort and energy efficiency for both residential and commercial spaces.

One of the standout features of these models is their advanced inverter technology. This allows the air conditioners to adjust the compressor speed according to the cooling requirements of the room. As a result, these units can cool spaces rapidly while consuming less energy compared to traditional models. The inverter technology not only contributes to energy savings but also ensures a quieter operation, making them ideal for bedrooms and workspaces.

The HR series models are equipped with multiple cooling modes, allowing users to select the most appropriate setting based on their comfort needs. Whether it's a hot summer day or a mild evening, users can tailor the temperature to their liking. Additionally, the models come with a sleep mode that gradually adjusts the temperature, providing a comfortable sleeping environment while saving energy.

Another significant characteristic of these air conditioners is their energy efficiency ratings. Many of the HR series units boast high SEER (Seasonal Energy Efficiency Ratio) ratings, indicating their effectiveness in cooling while minimizing electricity consumption. This is particularly beneficial for environmentally conscious consumers looking to reduce their carbon footprint.

Furthermore, the HR30D2VAR, HR18D2VAR, HR36D2VAR, and HR24D2VAR models incorporate robust air filtration systems designed to improve indoor air quality. These filters capture dust, pollen, and other allergens, making it an excellent choice for those with respiratory issues or allergies. Regular maintenance is also simplified, as filters can be easily accessed and cleaned or replaced.

Connectivity is another feature that enhances user experience. Many of the Haier air conditioning units in this series come with smart technology compatibility, allowing users to control their air conditioner through their smartphone or smart home systems. This remote control capability enables adjustments even when users are away from home, providing convenience and energy management.

In summary, the Haier HR30D2VAR, HR18D2VAR, HR36D2VAR, and HR24D2VAR air conditioners combine advanced technologies such as inverter operation, high energy efficiency, robust filtration systems, and smart connectivity. These features make them suitable for a variety of settings, ensuring comfort and ease of use for homeowners and businesses alike.