Emerson CKS2000N, CKS2005N Operating Instructions, Setting the TIME, the First Time, Date Display

Page 6

OPERATING INSTRUCTIONS

SETTING THE TIME, THE FIRST TIME

IMPORTANT:

The first time you connect your new SmartSet® clock radio to the AC outlet the internal computer will automatically set the time correctly for the Eastern Time Zone, which is the initial default setting. The display will scan for a few seconds and then set the correct month, date, day and time in the Eastern zone. If you live in the Eastern Time zone, there’s nothing else to do. Your clock is set correctly and running.

If you do not live in the Eastern Time zone you must change the default zone display to your own zone. You only do this one time and the SmartSet® will remember the new default zone setting and will always return to that setting after a power interruption.

There are 7 time zones programmed into your SmartSet® clock radio as follows:

Zone 01

-

Atlantic Time

Zone 02

-

Eastern Time

Zone 03

-

Central Time

Zone 04

-

Mountain Time

Zone 05

-

Pacific Time

Zone 06

-

Yukon Time

Zone 07

-

Hawaiian Time

To change the default time zone display, depress the Time Zone button. The word “ZONE” appears in the main display, and the number “02” will appear on the month/date display, indicating that the default zone is Zone 2, Eastern Time. Hold the Time Zone button and then press either the Up or Down buttons until your own time zone appears on the display, then release the buttons. The clock display will change to the correct time in the time zone you selected. The clock will always return to the correct time in the zone you selected after every power interruption. If you move to a different time zone, simply change the default zone display to the new zone and the SmartSet® will remember that setting for you.

DATE DISPLAY

The correct month and date appear in the small display. The month and date are expressed numerically in the MM/DD format. For example, May 21st will be displayed as (5. 21). This display adjusts automatically for months of different lengths. For example, at midnight on February 28th (2. 28), the display will automatically change to March 1st (3. 1), unless it is a Leap Year, in which case the display will change to February 29th (2. 29).

5

Image 6
Contents With SmartSet Congratulations Important Notes FCC InformationUnpacking and SET UP Power SourcePreparation for USE Location of Controls and Indicators Top PanelSetting the TIME, the First Time Operating InstructionsDate Display Adjusting the Wake UP Times Daylight Saving and Leap Year AdjustmentsManual Time Adjustments Year DisplaySelecting the Alarm Mode Checking the Wake UP Times and Alarm ModeListening to the Radio Antenna InformationWake to Radio Wake to Buzzer Snooze AlarmSleep to Music Timer Radio and Buzzer OperationChanging the Lithium Battery Dimmer ControlResetting the Clock After a Total Memory Loss Be Careful not to Lose These Small ScrewsImportant Note Care and Maintenance Emerson Radio Corp Limited Warranty Emerson

CKS2005N, CKS2000N specifications

The Emerson CKS2000N and CKS2005N are advanced temperature and humidity data loggers designed for a wide array of applications in various industries. These devices are particularly invaluable for sectors such as pharmaceuticals, biotechnology, food storage, and environmental monitoring. Their robust build and reliable data collection capabilities make them essential tools for maintaining optimal conditions and ensuring compliance with regulatory standards.

One of the standout features of the CKS2000N and CKS2005N is their high-precision sensors. The devices are equipped with sophisticated temperature and humidity sensors, offering accuracy typically within ±0.5 °C for temperature and ±3% for relative humidity. This precision is crucial for applications that require strict environmental controls to prevent spoilage or deterioration of sensitive materials.

Connectivity is a key aspect of these models. Both the CKS2000N and CKS2005N support a variety of communication interfaces, including USB and RS232, allowing easy connection to computers for data transfer and analysis. Additionally, they can seamlessly integrate with various management software solutions, providing enhanced data visualization and reporting capabilities.

The user-friendly interface of these data loggers makes operation straightforward. They feature an intuitive display that provides real-time readings of temperature and humidity levels, enabling users to monitor conditions at a glance. Furthermore, the devices come with programmable alarm settings that notify users of any deviations from predefined thresholds, facilitating timely interventions to mitigate risks.

Battery life is another important feature, with the CKS2000N and CKS2005N designed for long-term use without frequent replacements. Their efficient power management systems enable extended periods of operation, ideal for continuous monitoring in critical environments.

For enhanced functionality, these data loggers often incorporate advanced data storage capacities, allowing them to record thousands of data points. This feature is essential for retrospective analysis and trend spotting, making it easier to verify compliance with industry standards.

The Emerson CKS2000N and CKS2005N represent sophisticated solutions for environmental monitoring. Their combination of high accuracy, user-friendly operation, and advanced connectivity options makes them ideal for professionals who demand reliable data collection in critical applications. Whether for compliance, quality assurance, or product integrity, these data loggers meet the modern demands of diverse industries.