7) Chassis Final Connections

With the chassis in place, you are now ready to begin chassis connections:

A.Move the thermostat switches to "OFF" and "AUTO." This will keep the thermostat from cycling the chassis until final connections are complete.

B.Connect the ductwork onto the 10" collar. Plastic wireties (field supplied) are suggested to secure the ductwork in place. Use 2 wire ties, one for each inner and outer flex duct sleeve.

C.Using the two 3/4" plugs supplied with the unit, plug two of the condensate drain holes. Connect a drain to the third condensate exit location. Be sure to use teflon tape or approved pipe sealant on all drain connections and plugs. (See Figure 10.)

D.For 208 Volt power only: you must move the transformer wire as shown in Figure 7, Page 9.

E.Review the Final Installation Checklist on Page 12 before replacing the power quick disconnect, reconnecting power to the chassis, plugging in the remote thermostat harness, or operating the chassis.

Figure 10

Drain Connection

and Location

 

 

71/8

3"

8

7/8"

 

 

 

Electrical shock and moving parts hazard can cause injury or death. If you have not done so, pull out the disconnect head found on the front of chassis before continuing instal- lation! Disconnect external power at the breaker.

RT4 Digital Thermostat

8) Final Installation Checklist

Correct line voltage?

Chassis deck level?

Plenum divider baffle installed?

Wall plenum caulked? Level? Flashing?

HACR type breaker/fuse?

CAUTION

17 x 21/8

Single circuit only?

The unit basepan has three (3) provisions (left, right, and rear) for connecting an external condensate drain.

A field supplied condensate drain system must be connected to one of the three (left, right, or rear) 3/4" FPT connections on the unit basepan. Use of rear fitting may result in staining of the outside wall.

The remaining two connections must be plugged using the two 3/4" pipe plugs (provided) and field supplied teflon tape or pipe joint compound.

The addition of a secondary drain pan may be required. Follow all applicable codes.

Failure to follow these procedures may result in serious property damage.

A field supplied secondary condensate pan may be applied. Check with local codes.

Ductwork connected?

Chassis weather seal in place?

Wall thermostat wired correctly?

Chassis inserted into plenum?

12

Image 12
Contents 000 18,000 BTU/h Table of Contents Vert-I-Pak Installation Recommendations Section I. General Specifications Vert-I-PakModel Identification GuideII. Installation Utility Closet DimensionsTypical Utility Closet Chassis Shown in Closet, on Optional PlatformWall Plenum and Architectural Louver Installation Wall Plenum & Outdoor Louver InstallationElectrical Data Electrical DataSample Nameplate see your chassis nameplate Electrical Requirements Electrical Rating TablesElectrical & Thermostat Wiring Diagrams Indoor Return Air Grille Installation Return Air Grille OptionsChassis Installation Slide-in View / Chassis InstallationDuctwork Preparation Final Installation Checklist Chassis Final ConnectionsDrain Connection Location RT4 Digital ThermostatIV. Service & Warranty III. Chassis OperationFriedrich Air Conditioning Company Vert-I-Pak Accessories Model Description Photo

A-SERIES specifications

The Friedrich A-SERIES is a groundbreaking advancement in the realm of HVAC technology, designed to provide efficient heating and cooling solutions for residential and commercial applications. Renowned for its innovative approach, the A-SERIES integrates cutting-edge features that enhance comfort while promoting energy efficiency.

One of the standout characteristics of the A-SERIES is its advanced inverter technology. This system adjusts the compressor speed based on the heating or cooling demand, resulting in significant energy savings. By optimizing energy consumption, users can enjoy a comfortable indoor climate without incurring exorbitant utility bills. This feature is particularly beneficial in regions with extreme temperature fluctuations, as it ensures that the system operates efficiently without excessive wear and tear.

The A-SERIES also boasts a sleek, compact design that allows for easy installation in various spaces. Whether it's a small apartment or a larger commercial building, the A-SERIES offers flexibility in terms of placement, ensuring that architectural aesthetics are maintained while maximizing functionality.

In terms of performance, the Friedrich A-SERIES is equipped with high SEER (Seasonal Energy Efficiency Ratio) ratings, which underscore its energy-efficient operation. This efficiency is complemented by a multi-stage filtration system designed to improve indoor air quality. With a combination of pre-filters and HEPA filters, the A-SERIES effectively captures dust, allergens, and other airborne contaminants, contributing to a healthier living environment.

The durability of the A-SERIES is another significant advantage. Constructed with high-quality materials, it is built to withstand harsh weather conditions while maintaining optimal performance. The system also features a robust warranty, offering peace of mind to users regarding long-term reliability.

Moreover, the Friedrich A-SERIES incorporates smart technology, allowing users to monitor and control their HVAC system remotely via a mobile app. This feature not only improves convenience but also aids in scheduling, ensuring that energy is not wasted when spaces are unoccupied.

In summary, the Friedrich A-SERIES stands out in the HVAC market for its innovative inverter technology, energy efficiency, and user-friendly features. With its sleek design, advanced filtration system, and smart capabilities, this series meets the modern demands for effective climate control while prioritizing sustainability and comfort.