RCA 18V100 service manual 9a appears on screen immediately, and Tester, Board must be replaced

Page 5

is indicated on the TV screen; if there is no trouble, the

cartridge sets up a test for the two keyboards.

NOTE: The Test Cartridge requires substitution

of the power unit during test. Use the special

500mA power unit (see Parts List) instead of the

original power unit.

1.Press and hold "Clear" button on Studio II console. In- sert Tester cartridge into slot while holding "Clear" button.

NOTE: Insert cartridge into console with label

side toward "Clear" button. Follow label directions concerning removal of conductive rubber strip covering the plug.

2. Release "Clear" button. A pattern similar to that of Fig.

 

9a appears on screen immediately, and Tester

begins its

 

scan of the system (indicated by the black streak moving

f

through the white field in the lower half of the pattern). If the

pattern fails to appear or a pattern other than that shown

appears, a faulty chip is indicated. Replace PC board.

In about 1 1 seconds, the first scan is complete. The display

shifts to the pattern shown in Fig. 9b with a white streak scanning a black field. This scan takes another 1 1 seconds. At

the end of the second scan, the system changes the pattern on

the lower half to a series of transient vertical white lines on

black and then a series of black lines on white. This sequence

takes about 2 seconds. At the end of this short sequence, the

pattern again shifts- to that illustrated in Fig. 9c. This indi-

cates all memories operational. A digit or digits appearing in

the "checkerboard" pattern in the center of the screen, as

shown in Fig. 9e, indicates chip failure in the PC board and

the board must be replaced.

r

If the checkerboard appears as in Fig. 9c, touch the keys

- one at a time - of Keyboard A, and then Keyboard B. As

 

each key switch closes, the digit on screen should change to a

 

checkerboard square. (If any digit remains on screen after key

 

actuation, the keyboard is defective and must be replaced

 

(see Page 11). When all key closures are complete (indicating

 

CATV

 

 

STUDIO

TV

 

CO-AX

CATV

 

SELECTOR

 

 

MATCHER

 

SWITCH

RECEIVER

 

 

 

 

BOX

 

 

 

 

 

ANTENNA

 

r

 

 

 

TERMINALS

 

Figure 6.

Selector Switch Box Connects Between CATV Cable

 

 

Matcher and Home Receiver

 

 

ANTENNA

 

TV

nc/i

 

 

TERMINALS

»- STUDIO II

 

 

 

£1

 

 

 

 

 

 

 

 

o

 

 

 

-T®~L

 

 

 

 

 

 

TO

 

 

 

STICKY TAPE

CONSOLE

Figure 8. Adjust Receiver for Sharp "Freeway" Display

(d)Operable Keyboards and Electronics

mmmm^m

(e)Bad Key A7 and Digital Failure

Figure 7. Selector Switch Box

Figure 9. Tester 1 Screen Patterns

Image 5
Contents Itc/i Table of Contents Keyboard ON/OFF Indicator Light Power SupplySelector Switch SwitchTo Antenna Power Test ProceduresSystem Checking System ConnectionsOne at a time of Keyboard A, and then Keyboard B. As 9a appears on screen immediately, and TesterBoard must be replaced £ sj Overall Block Diagram of Studio II SystemThree Numbers to be Added Keyboard Tests Punch up Addition game Key A5. Sound switch Must be onMalfunction. If Tester is unavailable, the keyboards can be Enter a series of wrong answers, beginning with A1 As eachWith the switch in the TV position, it disconnects the con Pletes the DC circuit between the console and power supplyComponents Coaxial cable from the console to the twin lead and comStudio II Console Assembly Console Disassembly Component Replacement ProcedureMinimize radiation of modulated carrier Saw. See for dimensionsScope Time-Base Locked to 60Hz Power Line Clock Frequency Adjustment ProcedureReconnect black, white and yellow leads from PC board Milliseconds or more sync on Line and vertical inputPC Board Packing and Shipment Exchange Plan DescriptionReturn Shipping Label Form 3E4589 RCA Distributor and Special Products Division Deptford NJ