FLOW CHART FOR TROUBLESHOOTING OF THE UNIT

Manual background Only a qualified professional should perform any repair service(s).

Manual background When replacing any electrical components they should be OEM factory components.

Manual background Be sure that any electrical components are properly wired and secured.

FLOW CHART FOR TROUBLESHOOTING OF THE UNIT

POWER

BREAKER/FUSE

TRIPPED

SUPPLY CORD NOT

PLUGGED IN OR IS

LOOSE IN POWER

RECEPTACLE

UNIT'S POWER CORD

Manual background TRIPPED

3 MINUTE TIME DELAY Manual backgroundManual background IS ACTIVATED

PLUG IN SECURELY THE SUPPLY CORD

RESET SUPPLY CORD'S LCDI

WAIT FOR THREE MINUTES

REPLACE SUPPLY CORD IF RESETTING DOES NOT CORRECT

TEMPERATURE SETTING IS NOT BELOW ROOM TEMPERATURE

SET TEMPERATURE SETTING ABOVE (HEATING MODE) OR Manual background BELOW (COOLING MODE)

ROOM TEMPERATURE

ELECTRICAL COMPONENT COMPR20ISED

TROUBLESHOOT ELECTRICAL Manual background COMPONENTS AND REPAIR OR REPLACE

TROUBLESHOOTING THE SEALED SYSTEM COMPONENTS

REPAIR OR REPLACED ALL COMPROMISED SEALED SYSTEM COMPONENTS

WEIGH IN UNIT'S SPECIFIC REFRIGERANT CHARGE

RE-TEST UNIT

---2---

Image 2
Contents FRIEDRICH Service & Parts ManualPortableAirConditioner Models PH14BFLOW CHART FOR TROUBLESHOOTING OF THE UNIT Conditioned Supply 60 F - 90 F Timer 12 Hour Timer - 1 setting On or Offunit unit turn unit ON Timer Setting 75 degrees F3 feet PH14B Page Accessory Items PARTS NAME PH14BPART# QUANTITYPART# PARTS LISTPH14B PARTS NAME