Friedrich P012B, P012A service manual Installing the window adapter kit

Page 14

Installing the window adapter kit

Note: The window adapter kit must be installed and connected for the air conditioner to work properly in Cool mode. The window adapter kit is not required when using the unit in Dehumidify or Fan modes.

Your window adapter kit has been designed to fit most standard vertical and horizontal window applications. However, it may be necessary for you to modify some aspects of the installation procedures for certain types of windows.

1.Open window.

2.Place window panel with extensions into window frame and adjust to width of window.

Window adapter kit may be installed vertically as well as horizontally. This installation may also be used for crank style windows.

3.Tighten the four screws on the window panel to secure the window panel extensions.

4.Close window.

5.The window adapter kit should now fit securely within the window frame and you can now attach the air exchange tubes. If you are having trouble attaching the air exchange tubes, you may attach the tubes prior to installing the window adapter kit.

Attaching the air exchange tubes to the air conditioner

1.Attach the tubes to the window adapter kit.

2.Attach the other end to the air conditioner.

To attach air exchange tubes: push tube onto tube adapter and twist until the tab is in place in the hole on the tube.

To remove air exchange tubes: twist the end until the tab is clear of the hole in the tube and pull off.

Do not attach the tubes if using the unit in dehumidify mode.

Maintain a clear distance (from walls, furniture, etc.) of at least 10 inches around the unit to allow proper air circulation and prevent damage to the unit.

Important: Do not over-stretch the exhaust tube or make any unnecessary bends in it.

12

Image 14
Contents Portable Air Conditioner Technical Support Contact Information Table Of Contents Important Safety Information Electrical HazardsRefrigeration System Hazards Mechanical HazardsFire Damage Hazards IntroductionRegarding the Portable Air Conditioner Water Damage HazardsUnit Introduction 00001 PortableDesign Series Technical Specifications P09A and P12A 235 24.7 40.5Precautions for USE Explosion HazardControl Panel Operation Remote Control Air Conditioner Remote ControlWindow Adapter KIT Installation Window adapter kitInstalling the window adapter kit Attaching the air exchange tubes to the air conditionerDraining Water Condensation HandlingInternal Water Level Permanent DrainageCleaning the air conditioner Maintenance / ServiceCleaning the air filter Prior to operating seasonsTroubleshooting Troubleshooting Refrigerator System Diagram Schematic Wiring Diagram First Year Second Through Fifth YearPage Page Technical Support Contact Information Friedrich AIR Conditioning CO
Related manuals
Manual 24 pages 41.01 Kb