Friedrich MR30C3F, MW30C3F specifications Error Contents

Page 15

ERROR CONTENTS

 

Display

 

Error

 

 

Error

Operation

Timer LED

 

 

 

LED

 

 

 

 

2 flash

Serial signal (reverse) error, at operation start up

 

 

 

 

 

 

3 flash

Serial signal (reverse) error, during oeration

 

 

 

 

Serial signal error

Normal

4 flash

Serial signal (forward) error, at operation start up

 

 

 

 

 

 

5 flash

Serial signal (forward) error, during operation

 

 

 

 

 

 

8 flash

Wired remote controller error

 

 

 

 

 

 

2 flash

Indoor temperature thermistor open / short

Indoor unit thermistor error

2 flash

 

 

3 flash

Heat exchanger middle thermistor open / short

 

 

 

 

 

 

 

 

2 flash

Discharge thermistor open / short

 

 

 

 

 

 

3 flash

Heat exchanger thermistor open

Outdoor unit thermistor error

3 flash

 

 

4 flash

Outdoor temperature thermistor open / short

 

 

 

 

 

 

 

 

8 flash

Compressor temperature thermistor open / short

 

 

 

 

 

 

2 flash

Forced automatic SW welded

 

 

 

 

 

 

3 flash

Main relay welded

Indoor unit control error

4 flash

 

 

4 flash

Power interruption error

 

 

 

 

 

 

7 flash

VDD permanent stop protection

 

 

 

 

 

 

8 flash

reverse VDD permanent stop protection

 

 

 

 

 

 

2 flash

Current trip error

 

 

 

 

 

 

3 flash

CT abnormal

Outdoor unit control error

5 flash

 

 

5 flash

Compressor location detection error

 

 

 

 

 

 

 

 

6 flash

Outdoor unit fan drive system abnormal

 

 

 

 

 

 

2 flash

Abnormal lock

Indoor fan motor error

6 flash

 

 

3 flash

Abnormal rotation

 

 

 

 

 

 

 

 

2 flash

Discharge Temperature abnormal

Refrigerant cycle error

7 flash

 

 

3 flash

Cooling high pressure abnormal rise

 

 

 

 

 

 

5 flash

Pressure switch trouble

 

 

 

 

 

 

2 flash

Active filter voltage trouble (second time)

Optional function error

8 flash

 

 

3 flash

Active filter voltage trouble (first time)

 

 

 

 

 

 

4 flash

PFC circuit error

 

 

 

 

Model information error

0.1 sec on/off

0.1 sec on/off

Model information error

 

 

 

 

2006.04.04

14

Image 15
Contents Wall Mounted type ContentsSpecifications 12-5/8 320 39-1/4 228 Outline and DimensionsOutdoor Unit Outdoor Refrigerant System DiagramCircuit Diagram Indoor PCB Circuit Diagram Controller PCB Assy Indicator PCB Assy Outdoor PCB Circuit Diagram K05CU-0503HUE-C1 TR PCB Assy I P M K05CZ-0503HUE-TR0 Power Supply PCB Capacitor PCB Assembly Error Contents Disassembly Illustration Models MW30C3F 2006.03.31 Model MW30C3F 3837 2006.05.12 2006.05.12 2618 4642 $576/,67 28722581,7 5HI Name and Shape Standard Accessories0602G3030