Product Description
The Magnum SG Control Module is an interface between the welding power source and the Magnum Spool Gun. The Control Module and Spool Gun combination provide a system for welding primarily with aluminum electrode wire using a con- stant voltage welding power source.
The Control Module provides control of both wire speed and gas flow. It also provides connections from the welding power cable, control cable, and gas hose from the power source and gas cylinder regulator to the spool gun.
The Control Module will operate with any power source that provides constant voltage welding output and has an output contactor.
Required Equipment
Specifications
Model: | Magnum SG Control Module |
Type: | K488 |
Power Requirements: Voltage | 115 VAC, 50/60 Hz |
Current | 0.5 amps maximum |
|
|
Welding Current Rating: | 250 amps at 60% duty cycle |
|
|
Motor Output: | |
|
|
Preflow Time: | |
Contactor Circuit Output: | Normally open relay contacts |
| (“Closure”) or 115 VAC; selectable |
|
|
Dimensions, H* x W x D | 10.0 x 8.25 x 9.0 inches |
*dimension includes handle | (254 x 210 x 229mm) |
|
|
Weight | 13 Lbs. (5.9kg) |
|
|
To operate the Magnum SG Control Module, the following equipment is required and ordered separately:
Magnum Spool Gun
Adapter
Power Source
The Control Module will operate with any Lincoln CV or CV/CC power sources, with many Lincoln
In general, power sources must have the following:
1.A constant voltage (CV) type welding output.
2.Capability to supply 115 volt AC power to the control module.
3.Optional for “cold electrode” switched welding output: An output contactor. It can be either of two types:
A.Switch closure:
B.115 VAC:
115 volts AC supplied from the control module to the power source.
A selector switch on the back of the control module is used to select which of these two types of control circuit is being used. It is imperative that this switch be set correctly before attaching to the power source. See “Setting the Mode Switch on Rear Panel” for more details.
Optional Accessories
Several accessories are optionally available for use with the
K488 control module, and they are as follows:
1.Three 10 ft. (3.0m) input cable assemblies are available and consist of control and electrode cables and gas line. The proper input cable assembly must be ordered in addi- tion to the control module; as none are included with the control module:
A.
B.
C.
2.K473 Spool Gun Extension Cable. 25’ extension cable extends distance between spool gun and K488 control module.
3.K518 Adapter for K469 Spool Gun. Adapts K469 spool gun to K488 Control Module or to K473 Extension Cable.
The control module is not required when connecting Magnum spool guns to Lincoln models
K492-10 K493-10
For convenience, here is a summary of needed equipment to use the various combinations of available Magnum spool guns and accessories: