OPERATION | ||
|
|
|
SAFETY PRECAUTIONS
Read entire section before operating this unit. Additionally, read the V300 operator’s manual before operating this unit.
WARNING
ELECTRIC SHOCK can kill.
•Do not touch electrically live parts such as output terminals or internal wiring.
•Insulate yourself from the work and ground.
•Always wear dry insulating gloves.
FUMES AND GASES
can be dangerous.
•Keep your head out of fumes.
•Use ventilation or exhaust to remove fumes from breathing zone.
WELDING SPARKS can cause fire or
explosion.
•Keep flammable material away.
•Do not weld on containers that have held combustibles.
ARC RAYS can burn.
•Wear eye, ear and body protection.
Observe additional Safety Guidelines detailed in the beginning of this manual.
GENERAL DESCRIPTION
The MIG Pulser is a
RECOMMENDED PROCESSES AND EQUIPMENT
The MIG Pulser/V300 combination can run the follow- ing processes:
GMAW-P
.035 steel, 100 - 700 IPM (90/10 Ar/CO2)
.045 steel, 75 - 400 IPM (90/10 Ar/CO2)
.035 stainless steel, 100 - 700 IPM (98/2 Ar/O2)
.045 stainless steel, 75 - 350 IPM (98/2 Ar/O2) 3/64 5356 Aluminum, 150 - 600 IPM (Ar)
The MIG Pulser/V300 combination can be used with all wire feeders recommended for the V300
OPERATIONAL FEATURES AND CONTROLS
The MIG Pulser has the following controls as standard: Arc Length (continuously variable), Peak Current (choice of Low, Medium and High), and Background Current (choice of Normal and High).
MIG PULSER