OPTIONAL

CONTROL PANELS

PROCESS CONTROL PANELS

POWER FEED 10 & 10 DUAL

M PANEL

This optional control panel allows the user to select the type of output desired: CV-MIG/CV Gas-Shielded, Flux-Cored (Outershield,Metal-Cored), Flux-Cored (Innershield), or CC- Stick (Soft)/Gouge. The “Arc Control “ varies inductance in the CV modes and arc force in the CC-Stick mode.

Order K1542-6.

MX2 PANEL

This optional control panel adds CC-Stick (crisp) mode and a flexible welding setup.

Shielding gas preflow: 0.1 to 2.5 seconds or OFF.

Run-in wire feed speed: Adjustable for optimum start 75 to 150 inches per minute or OFF.

Arc Control: Inductance control adjusts arc characteristics to operators preference.

Burnback: Time the arc stays on after the wire feed stops. 0.1 to 0.25 seconds or OFF.

Post Flow: Time the shielding gas flows after the weld stops. 0.1 to 10.0 seconds or OFF.

Crater Fill: Allows a second procedure used in the 4-step trigger mode. Use for aluminum crater fill welding or a second procedure.

Order K1542-11.

MSP2 PANEL

This optional control panel has the complete setup selections of the MX panel. This panel also adds synergic CV and pulse welding programs. Required to use Wave Designer software.

Order K1542-12.

6

Image 6
Contents Power Wave Welding Systems Advantage Lincoln Power SourceWire Feeder System WideTechnical Specifications Power SourceCloser Look System SelectionPower Feed 10 Dual Dual Procedure / Memory Power Feed Dual Procedure PanelDual Procedure / Memory Optional Control PanelsPower Feed 10 & 10 Dual Panel MX2 PanelMSP2 Panel NEW Wire Drive AdvantagesFeed Plate GUN Receiver Bushings Magnum GunsDrive Rolls Split Wire Guide Kits Roll, and Split Wire GuideLINC-NET TM Control Cables Recommended OptionsRecommended Options Software Lincoln Electric Company