White Rodgers 36H SERIES Outlet Pressure Adjustment, Turn off all electrical power to the system

Page 5

ADJUSTMENT

Low regulator cover screw (two stage only)

Regulator adjust screw

Regulator spring

Pilot cover screw

Pilot gasket

Pilot adjust screw

Single stage and two stage high regulator cover screw

Regulator adjust screw

Regulator spring

7.Turn off all electrical power to the system.

8.Remove manometer hose and fitting from outlet pressure tap.

9.Replace outlet pressure tap plug and tighten (clockwise 40-60 in-lb.)

10.Turn on system power and set thermostat to call for heat.

11.Using a leak detection solution or soapsuds, check for leaks at pressure tap plug. Bubbles forming indicate a leak. Shut off gas and Fix all leaks immediately.

Outlet pressure tap

Figure 5. Pressure Adjustment

Outlet Pressure Adjustment

1.Turn off all electrical power to the system.

2.Remove plug and install hose barb fitting and manometer to pressure tap on outlet end of valve. See fig. 5.

3.Turn on system power. Set thermostat to call for heat (low stage for two-stage systems). Main burner should light. Proceed to step 6 for single stage systems.

4.(2-stage only) Remove regulator cover screw from the low outlet pressure regulator adjust tower (fig. 5) and turn

screw clockwise ( ) to increase pressure, or coun-

terclockwise ( ) to decrease pressure. Always adjust regulator according to original equipment manufacture’s specifications listed on the appliance rating plate. Replace regulator cover screw.

5.(2-stage only) Set thermostat to call for high stage.

6.Remove regulator cover screw from the single stage or high outlet pressure regulator adjust tower (fig. 5) and turn

screw clockwise ( ) to increase pressure, or coun-

terclockwise ( ) to decrease pressure. Always adjust regulator according to original equipment manufacturer’s specifications listed on the appliance rating plate. Replace regulator cover screw.

Pilot Flame Adjustment

(Models 36H3X and 36H6X only)

If the pilot frame is low and does not engulf the bulb of the mercury flame sensor, the system will not energize the main valve. If pilot gas pressure is too high, gas will sputter past the ignition electrode, and may not ignite. High pilot gas pressure may also cause the flame to lift off the burner, causing the flame sensor bulb to sense “low” heat.

To adjust the pilot gas pressure, remove the cover screw (See fig. 5). To reduce pilot pressure, turn the pilot adjust screw

(beneath the cover screw) clockwise ( ) . To Increase pilot pressure, turn the pilot adjust screw counterclockwise (

). Replace and tighten cover screw.

NOTE

For gas to gas conversion, consult your dealer for appropriate conversion kit.

5

Image 5
Contents Specifications Installation InstructionsContents DescriptionPrecautions Models 36H3X and 36H6X require a pilot Connection InstallationLoosen the pilot fitting until it is finger-tight GAS and FIX ALL Leaks ImmediatelyPressure Regulator Adjustment AdjustmentSystem Wiring Turn off all electrical power to the system Outlet Pressure AdjustmentFor Your Safety What to do if YOU Smell GAS Lighting Instructions For Your Safety Read Before OperatingOperating Instructions To Turn OFF GAS to ApplianceUSO DE Encendido DE InstruccionesUsar DE Antes LEA Seguridad SU Para Artefacto AL Llega QUE GAS EL Apagar ParaPiloto del presión la Reducir Para AjustePiloto DEL Llama LA DE Ajuste Ajuste Presión DE Regulador DE AjusteEléctricas Conexiones Instalación Etapasola unade MoelosTuberías LAS DE Conexiones PrincipalesInstalación Inmediatamente PérdidasMáx pies/libra PrecaucionesControl Explosión UNA Y/O Incendio UNInstalación LA Para Instrucciones DescripciónContenido Materiales Daños Y/O Personales