Friedrich US12C30, US12C10, US14C30, US10C30, US10C10 manual Electrical Parts, Compressor, Capacitor

Page 12

2.2.3 SHROUD

1.Remove the fan. (Refer to section 2.2.2)

2.Remove the shroud. (See Fig. 9)

3.Re-install the components by referring to the removal procedures, above.

2.3 ELECTRICAL PARTS

2.3.1 MOTOR

1. Remove the cabinet. (Refer to section 2.1.2)

2. Remove the clamp cord and disconnect the wireFigure 9 housing in control box. (Refer to section 2.1.3)

3.Remove the turbo fan. (Refer to section 2.2.2)

4.Remove the fan. (Refer to section 2.2.2)

5.Remove the 4 or 2 screws which fasten the motor. (See Fig. 10)

6.Remove the motor.

7.Re-install the components by referring to the removal procedures, above.

2.3.2 COMPRESSOR

1.Remove the cabinet. (Refer to section 2.1.2)

2.Discharge the refrigerant system using a FreonTM Recovery System.

Install a valve for recovery before venting the Freon. Remove the valve when finished.

3.Disconnect the 3 leads from the compressor.

4.After purging the unit completely, unbraze the suction and discharge tubes at the compressor connections.

5.Remove the 3 nuts and the 3 washers which fasten the compressor. (See Fig. 11)

6.Remove the compressor.

7.Re-install the components by referring to the removal procedures, above.

2.3.3 CAPACITOR

1.Remove the control box. (Refer to section 2.1.3)

2.Remove the 1 screw

3.Open the control box

4.Disconnect all the leads on the capacitor terminals.

5.Re-install the components by referring to the removal procedures, above.

—12—

Figure 10

Figure 11

Figure 12

Image 12 Contents
Thru-the-Wall Series Contents Specifications Refrigerant R-410A Charge 1Ø, 230V/208V, 60Hz Btu/h 11500/11200 1Ø, 230/208V, 60Hz Btu/h 13,000/12,600 Features Mechanical Parts Front GrilleCabinet Control BOXAIR Handling Parts ORIFICE, and Turbo FANElectrical Parts CompressorCapacitor Power Cord Electronic Control BoardRefrigeration Cycle CondenserEvaporator Capillary TubePage Pulling Vacuum Outside Dimensions Piping SystemTroubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Complaint Cause Remedy Wiring Diagram Circuit DiagramExploded View W0CZZ CAPACITOR,FILM,BOX BRACKET,MOTOR W0CZZ CAPACITOR,FILM,BOX LocNo Description US12C10 LocNo· Description US12C30 LocNo· Description US14C30 Friedrich AIR Conditioning CO
Related manuals