Lincoln Electric 450 K466-6, K466-7 and K466-10 Installation Wirematic, K466-4 KIT, K466-7 KIT

Page 12

 

B-2

 

INSTALLATION

B-2

 

 

 

 

 

 

 

 

 

 

 

b. Remove the molded gas plug fitting on the side of the

 

K466-5 KIT

 

 

 

feeder end handle and replace it with the barbed brass fit-

 

 

 

 

 

ting provided in the kit. The included wrench will fit both

 

 

 

 

 

the gas plug and barbed fitting.

 

 

 

 

 

 

 

c. Attach the phone plug connector of the gun control cable

 

 

 

 

 

provided to the trigger connector on the front of the

 

 

 

 

 

Hobart feeder.

 

 

 

 

 

 

 

 

 

K466-6, K466-7 and K466-10 Installation (Wirematic,

 

 

 

 

 

 

 

 

d. Place one tubing clamp onto each end of the flexible tub-

Hobart Series 2000 Feeders and Lincoln 10 Series Feeders)

 

 

ing provided, approximately 2” (51 mm) in from each end.

 

 

 

 

 

Slide one end of the tubing onto the barbed connector on

 

a. Remove brass cable connector (see Figure B.1) from the

 

 

the feeder end cable handle (step b) and move the clamp

 

connector kit and screw it onto the feeder end of the gun

 

 

down near the end of the tube to assure a good gas seal.

 

cable. Tighten the connection with the wrench provided.

 

 

 

K466-4 KIT

 

 

 

b. Check that the molded gas plug fitting is sealing the gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fitting hole in the side of the feeder end handle.

 

 

 

 

 

 

 

 

c. Attach the gun control cable provided to the trigger con-

 

 

 

 

 

 

 

nector on the front of the wire feeder.

 

 

 

 

 

 

 

K466-6 KIT

 

 

 

K466-5 INSTALLATION (For L-Tec Feeders)

 

 

 

 

 

 

a. Remove brass cable connector (see Figure B.1) from the

 

 

 

 

 

K466-5 kit and screw it onto the feeder end of the gun

 

 

 

 

 

cable. Tighten the connection with the wrench provided.

 

 

 

 

b. Check that the molded gas plug fitting is sealing the gas

fitting hole in the side of the feeder end handle.

K466-7 KIT

 

c. For L-Tec machines that require trigger lead connections

 

to be made at a terminal strip located within the machine

 

(L-Tec 225), a gun control cable with forked terminals is

 

 

 

provided. Connect the terminated leads to the terminal

 

K466-10 KIT

strip. For a machine that requires a twist-lock gun control

 

cable connection, continue to use the L-Tec gun control

 

cable provided with the L-Tec wire feeder connector

 

assembly. Connect the twist-lock plug to the proper

 

receptacle on the machine.

 

 

 

 

FIGURE B.1

 

INSULATION TUBE (K466-1 ONLY)

BRASS CABLE

CONNECTORFEEDER END CABLE HANDLE

 

MOLDED GAS

SET SCREW

PLUG

 

LINER ASSEMBLY (LINER BUSHING TO BE SEATED TIGHT AGAINST BRASS CABLE CONNECTOR

GUN HANDLE

CLAMPING SCREWS

 

GUN TUBE

 

9/16”(14.3mm)

 

LINER TRIM

 

LENGTH

 

GAS DIFFUSER

INSULATOR

 

GAS NOZZLE

MAGNUM® PRO 250, 350, 450 & 550 AMP

Image 12
Contents Safety Depends on You Magnum PROSafety California Proposition 65 WarningsElectric ShOCK can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Thank You Table of Contents General Description General DescriptionDescription Gun Contact Tips Gas Product Magnum PRO 250, 350, 450 Installation K466-1& -8 Installation For Lincoln FeedersK466-2 KIT K466-3 Installation For Miller Feeders K466-3 KIT K466-4 Installation For Hobart FeedersK466-6, K466-7 and K466-10 Installation Wirematic K466-6 KIT K466-5 Installation For L-Tec FeedersK466-4 KIT K466-7 KITInstallation Contact TIP and GAS NOzzLE Installation Connection to hOBART FeedersConnection to Lincoln WIREMATIC, hOBART Series 2000 Feeders Connection to L-TEC Adapted FeedersOperation ElectroDes AnD equiPmentMaintenance Gun cAblesGUN END Figure D.3 Figure D.4 TROUBLEShOOTING Problems Problems Symptoms Possible Cause Remedy Magnum PRO 250, 350, 450 Precaucion Aviso DE