Technical Specifications- Magnum X-Tractor 1GX

INPUT

Sales Spec

Input Voltage

Input Current

K173-2

120V, 1ø 50/60 Hz

10 A (light duty, intermittent use)

VACUUM SPECIFICATIONS

Air Flow without a hose

Air Flow with provided hose attached

96 ft3 / min (164 m3 / hr)

88 ft3 / min (149 m3 / hr)

FILTER LIFE

Approximately 400 lbs. of electrode under normal solid wire GMAW conditions

OPERATING SOUND LEVEL

75 dBA

AUTOMATIC SHUT OFF DELAY

5 to 25 seconds (user adjustable)

PHYSICAL DIMENSIONS

 

 

 

 

HEIGHT

WIDTH

DEPTH

WEIGHT

14.4” (365 mm)

8.1” (205 mm)

32.5” (825 mm)

34 lbs (15.5 kg)

 

 

 

 

MAGNUM X-TRACTOR 1GX

Image 8
Contents Magnum X-Tractor 1GX Safety Electric Shock can killARC Rays can burn Fumes and Gases can be dangerousWelding Sparks can cause fire or explosion Cylinder may explode if damagedFor Engine powered equipment May be dangerousPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Vacuum SpecificationsGeneral Description Safety PrecautionsConnection to Power Supply and Welding Power Source Connection to the Gun and Cable Assembly Locating the Vacuum SourceOperating Instructions Safety InstructionsOperation Maintenance Routine and Periodic MaintenanceTroubleshooting HOW to USE Troubleshooting GuidePossible Areas Magnum Tractor 1GX PartsMagnum X-TRACTOR Vacuum Source 202-K.1 Precaucion Aviso DE