Craftsman 921.153120 Operating Procedures, Daily Start-Up Procedures, Daily Shut-Down Procedures

Page 7

Operating Procedures

Daily Start-Up Procedures

1. Set the Auto-On/Off lever to the Off position.

2. Inspect the air compressor, air hose, and any accessories/tools being used for damage or obstruction. If any of these mentioned items are in need of repair/ replacement, contact your local authorized service dealer before use.

3. Close the drain valve.

4. Check the oil level of the pump.

5. Connect the air hose to the quick connect socket on the regulator assembly by inserting the quick connect plug on the air hose into the quick connect socket. The quick connect socket collar will snap forward and lock the plug into place providing an air tight seal between the socket and plug. To release the air hose push the collar back on the quick connect socket.

6.Plug the power cord into the proper receptacle.

7.Turn the Auto-On/Off lever to the On-Auto position and the compressor will start and build air pressure in the tank to cut-out pressure and then shut off automatically.

8.Adjust the regulator to a PSI setting that is needed for your application and be sure it is within the safety standards required to perform the task. If using a pneumatic tool, the manufacturer should have recommendations in the manual for that particular tool on operating PSI settings.

9.The air compressor is now ready for use. The following inflation and cleaning accessories packaged with this unit should only be operated at maximum pressure

of 90PSI: blow gun, rubber-tapered nozzle, inflation needles, adapter, and blow gun adapter.

���

���

8

5

 

7

6

��� 1

3

Daily Shut-Down Procedures

1. Set the Auto-On/Off lever to the Off position.

2. Unplug the power cord from the receptacle.

3. Set the outlet pressure to zero on the regulator.

4. Remove any air tools or accessories. When draining the tank, always use ear and eye protection. Drain the tank in a suitable location; condensation will be present in most cases of draining.

5. Open the drain valve allowing air to bleed from the tank. After all of the air has bled from the tank, close the drain valve to prevent debris buildup in the valve.

4

CAUTION

When draining the tank, always use ear and eye protection. Drain the tank in a suitable location; condensation will be present in most cases of draining.

WARNING

Water that remains in the tank during storage will corrode and weaken the air tank which could cause the tank to rupture. To avoid serious injury, be sure to drain the tank after each use or daily.

5

Image 7
Contents 1HP Sears, Roebuck and Co., Dept WA Hoffman Estates, IL ONE Year Full Warranty on Craftsman AIR CompressorImportant Safety Instructions and Guidelines Safety SymbolsGlossary SpecificationsDuty Cycle Parts & Features Extension Cords Installation & AssemblyAssembly Break In ProceduresDaily Start-Up Procedures Operating ProceduresDaily Shut-Down Procedures Storage MaintenanceItems to Check/Change Before each use Or daily Problem Possible Correction Troubleshooting GuideAir Compressor Model 15312 Parts List