Anton/Bauer 2700, 2400 owner manual Autocal Feature

Page 12

When testing is completed, the LCD Main Display will indicate “TEST DONE”. To display or print test results:

1.Press the DISPLAY button on the PowerCharger front panel to scroll to the Primary Position Display for the battery tested.

2.Press the TEST button. The LCD will display the capacity of the battery in ampere hours. If a printer is attached, performance data will simultaneously be printed out with all battery identification information. Consult your battery owners manual for warranty information and cell capacity ratings.

Remove battery only when test data has been viewed or printed. Test data is retained only while the battery is on the PowerCharger. Once battery is removed, data is no longer available.

“AUTOCAL” Feature

When a DDM is installed in the PowerCharger, a special InterActive mode is automatically enabled for DIGITAL batteries placed on the PowerCharger at any time. The PowerCharger will interrogate the status of the DIGITAL battery to determine whether the battery has received a “learning” cycle or “calibrate” cycle within certain parameters. This “learning” typically occurs in normal equipment operation, however, if the battery has not been fully charged and discharged in some time, a “double arrow” or “calibrate” indication will appear on the battery. The DIGITAL battery will continue to function normally with this indication. It is a request by the battery to fully charge and discharge the battery to the “EOD” point at the next opportune time so that the battery can verify its capacity. See DIGITAL battery Owner’s Manual for complete description of this indication.

The PowerCharger with DDM will detect a request from the DIGITAL battery and automatically enter an AUTOCAL mode when the battery is placed on the charger. This mode is indicated by the PowerCharger with an audible alert and a message in the LCD advising that the AUTOCAL routine has been called. This mode can be canceled, for example, if time constraints do not allow for the test to be completed. The mode is identical to the charge-discharge-charge previously described.

The AUTOCAL mode can be canceled by following the prompts appearing in the LCD, using the TEST button to cancel the test. If the test is not canceled, it will commence automatically.

When the AUTOCAL operation is complete, the battery will be fully charged and ready for use.

10

Image 12
Contents PowerCharger Table of Contents Standard Features IntroductionExpansion Options BackSafeguards Fuse TYPE/REPLACEMENTGROUNDING/EARTHING OperationCharging ApplicationsThree Stage Charging Methodology Wait Ready Charge PropacLED Indications LED Indication MeaningPriority Battery Function DDM DIAGNOSTIC/DISCHARGE ModuleStandard on Model Quad To Operate The PowerCharger with DDM Autocal Feature XM Charge Expansion Module Operation AS DC Camera Supply from MainsPower Loss Memory Mode FCC NoticeWarranty Worldwide standard