Xantrex Technology IP1012 AL manual Planning for AC Loads, Type of Loads

Page 16

Operation

Planning for AC Loads

AC load

AC load refers to an AC appliance you want to operate from the inverter/

 

charger. Loads include most appliances that you can plug into a standard

 

120 volt household electrical outlet.

Variables

The IP1012 AL inverter/charger can power a wide range of loads. The

affecting AC

size of the load and the length of time you can operate it depends on

loads

variables such as:

 

type of load,

 

ambient temperature,

 

• size, state of charge, temperature, and condition of batteries.

The larger your battery capacity and the higher the state of charge, the longer the inverter/charger can run your AC loads. Battery capacity is reduced as battery temperature lowers.

Type of Loads

AC loads

 

The way in which an AC load draws power may determine how

 

effectively it can be powered from the inverter/charger.

Resistive loads

Toasters, coffee pots, and incandescent lights are examples of resistive

 

loads which do not need a high start-up current to start running. They use

 

a resistive heater element to generate heat or light. They are the simplest

 

and easiest loads for an inverter/charger to run. Large resistive loads, such

 

as electric stoves and water heaters, are impractical since their high power

 

requirements quickly drain the batteries.

Inductive loads

TVs, VCRs, stereos, computers, and electric motors (power tools,

 

vacuum cleaners, for example) are examples of inductive loads which

 

surge on start up. They require a high startup current compared to a

 

resistive load such as a toaster or coffee pot. Depending upon its size, the

 

motor can take as much as six times of its operating current to start than it

 

does to keep it running once it has started. This surge can sometimes

 

exceed the inverter/charger’s maximum output rating and the inverter will

 

shut down.

2–2

975-0337-01-01

Image 16
Contents IP1012 AL Inverter/Charger with Ignition Protection Page IP1012 AL Inverter/ Charger with Ignition Protection Date and Revision Purpose ScopeAudience OrganizationRelated Information Conventions UsedFollowing conventions are used in this guide Important Safety Information General PrecautionsPrecautions When Working With Batteries Precautions for Using Rechargeable DevicesContents Specifications TroubleshootingCommon Problems Blinking Lights on the Remote Switch Introduction Inverter/charger Features About the unitOperating Features Feature DescriptionIntroduction Operation Planning for AC Loads Type of LoadsConditions or cabin heat from heaters Ambient TemperatureWatts continuous Calculating Size of an AC Load Planning for AC Loads Appliance Watts Minutes Hours Running the Alternator While Operating AC and DC Loads OverloadedOperation Using the Remote Switch Switch positionLights will behave like this FloatRunning in Extremes Of Hot or Cold Temperatures Operating the Inverter/ChargerTurning the Inverter On and Running Loads Restarting After a ShutdownBattery Charging Using ShorepowerMiscellaneous Hints AutomaticMaintenance Maintaining the Inverter/charger Checking TerminalsDisconnecting Disconnecting and Connecting the BatteriesConnecting Replacing the Fuse To replace the fuse Lift the fuse cover off as shown in FigureRemoving and Reconnecting AC Cables To remove the AC cablesTroubleshooting Troubleshooting Common ProblemsBlinking Lights on the Remote Switch Troubleshooting reference2Charger indicator blink patterns Specifications Physical Specifications Physical specificationsInverter Specifications Charger Specifications Shutdowns and RestartsTransfer and General Specifications Transfer and general specificationsRating Curves and Charging Profiles Time minutesFigure A-3Three-stage charging profile Page Index IX-2 975-0337-01-01 Warranty and Return Information WarrantyDisclaimer ProductReturn Procedure Return Material Authorization PolicyExclusions Out of Warranty Service Information About Your SystemSerial Number Product Number Purchased From Purchase DatePage Xantrex Technology Inc
Related manuals
Manual 52 pages 11.23 Kb

IP1012 AL specifications

The Xantrex Technology IP1012 AL is a high-performance inverter designed to meet the needs of mobile and off-grid applications. With its compact and lightweight design, the IP1012 AL is ideal for recreational vehicles, boats, and even remote cabins, providing a reliable source of power wherever it is needed. One of the standout features of this inverter is its ability to deliver a continuous output of 1000 watts, with a surge capacity of up to 2000 watts. This makes it capable of powering a range of devices, from laptops and televisions to small appliances and power tools.

The Xantrex IP1012 AL utilizes advanced sine wave technology, which produces a pure sine wave output that is essential for sensitive electronic equipment. This technology ensures that devices such as computers and medical equipment operate safely and efficiently, minimizing the risk of damage from power fluctuations. Additionally, the inverter is equipped with built-in safety features, including thermal shutdown protection, overload protection, and short circuit protection, ensuring that both the inverter and connected devices are safeguarded against potential electrical hazards.

Another key characteristic of the IP1012 AL is its user-friendly interface, featuring LED indicators that provide real-time information on the inverter's status and performance. The inverter also boasts a wide input voltage range, accommodating various battery types and configurations, making it versatile and adaptable for different applications. Its lightweight aluminum chassis further enhances its portability, making it a perfect choice for outdoor enthusiasts and those seeking a dependable power source for camping or hiking trips.

Furthermore, the Xantrex IP1012 AL is designed for efficiency, with a built-in energy-saving mode that reduces power consumption when the inverter is not in use. This feature prolongs battery life and maximizes the efficiency of the overall system. The inverter connects easily to battery banks, and its compact form factor allows for convenient installation in tight spaces.

In summary, the Xantrex Technology IP1012 AL is a powerful and reliable inverter that offers essential features for a variety of mobile and off-grid applications. Its advanced sine wave technology, safety features, user-friendly interface, and energy efficiency make it an excellent choice for anyone looking for dependable portable power. Whether you're a weekend warrior or a full-time RV traveler, the IP1012 AL ensures you have the energy you need when you need it.