T-Tech 2001, 3001 owner manual Troubleshooting, Possible Cause Solution

Page 7

TROUBLESHOOTING

PROBLEM: Unit does not jump start.

POSSIBLE CAUSE

SOLUTION

Poor grip connection

Check grip connection

Low/defective battery

Load test/charge/replace battery

Loose jumper cable connection to battery

Tighten battery connections

PROBLEM: Unit does not charge.

 

POSSIBLE CAUSE

SOLUTION

Poor grip connection

Check grip connection

Faulty 110 AC outlet

Check or change outlet

Bad plug on unit

Check continuity of plug pins/replace plug

Loose/defective connections

Check unit for loose connections

Defective amp gauge

Replace gauge

Faulty charger

Replace charger

PROBLEM: Unit does not inflate tires.

 

POSSIBLE CAUSE

SOLUTION

Low/defective battery indicated by

Recharge/replace battery

clicking of circuit breaker

 

Loose/defective connections

Check unit for loose connections

Defective air pressure switch

Replace pressure switch

Defective "On/Off" switch

Replace "On/Off" switch

Defective compressor

Replace compressor

For Diagnostic and Repair Help, call the Clore Automotive

Technical Service Hot Line at (800) 328-2921 or visit www.solaronline.com

Image 7
Contents Model Nos /3001 Do not TIP Unit or LAY Unit Flat with Battery Installed Personal Safety Precautions Safety InstructionsGrounding and AC Power Connection Instructions Battery Selection Selecting and Installing the BatteryOperating the Unit AS a Jump Starter Operating InstructionsOperating the Unit AS AN AIR Compressor Model No Only Possible Cause Solution TroubleshootingRead Carefully Before Operating Unit Limited WarrantyWarranty Technical Support Registration Business Reply Mail