Dimplex 6100770000, 6100790000 installation instructions MULTI-DIRECTIONAL Grille Orientation

Page 1

MULTI-DIRECTIONAL GRILLE ORIENTATION

FOR USE WITH 610070000/6100790000 WH SERIES HEATERS

RECESS BOX

WIRING ACCESS

FIGURE #1

Fan Forced Wall Heater

Model WH Series

6100790000 / 6100770000

ALTERNATE MULTI-DIRECTIONAL GRILLE ORIENTATION

REGISTER

GRILLE

ORIENTATION

NOTE: MAINTAIN A MINIMUM CLEARANCE OF 8” FROM ADJACENT WALLS, FLOORS AND CEILINGS ON ALL FOUR SIDES OF THE GRILLE

INSTALLATION INSTRUCTIONS

Congratulations on purchasing a small wall heater from Dimplex North America. Your heater is manufactured using the highest quality materials and workmanship and will provide many years of trouble free service. This heater is designed for permanent installation only, care should be taken to install according to the following instructions. All required clearances should be maintained, in addition all electrical wiring and connections should comply with local electrical codes.

Note : It is extremely important to read all information labels. Care must be taken to ensure that the heater is rated the same voltage as the electrical supply wires. Failure to do so could result in unsafe heater operation as well as damage to the unit. If replacing an existing heater, check the labels of the old heater to ensure the voltage of the new heater is compatible.

All units should be controlled by means of a regulating thermostat,certain models only are provided with built in thermostats, check the Model Key Information section for verification. Wall thermostats should comply with the voltage and wattage of all heaters on the circuit. Built in thermostats are not suitable for Register Grille Models.

All installations require the following components

1)Recess Mount Box ( Model 6100831000 )

2)Heater Assembly ( See nameplate Label )

3)Grille ( Either Multi- Directional Style or Register Style )

An optional Surface mount box is available for installations that are not recessed in wall cavity.

STEP 1 – Placement

All units are designed for placement in either interior or exterior walls. Care should be taken to provide a minimum of 8" clearance from floors, ceilings and adjacent walls. Once installed, the airflow through the heater should not be blocked in any way. Maintain 3ft clearance of objects from the front of unit. Maintain a spacing of 3ft between heaters in order to prevent re-circulation of heated air. Insulation surrounding the back and sides of the recess mount box will not affect performance. Ensure insulation is rated for temperatures up to 85oC.

Note: Certain flooring and wall covering materials ( particularly those incorporating clear vinyl materials tend to distort at temperatures in the vicinity of 60 C ( 140 F ). Material shall be checked prior to installation to determine if discoloration will occur. Units are not approved for placement in floors or ceilings. Do not install in any area where combustible vapors, gases, dusts or liquids are present. Fire or explosion may occur.

STEP 2 – Mounting The Recess Box

Determine the desired orientation of unit. Provide an opening in wall 14 ¼” x 7 5/8" x 3 3/8" deep minimum. Care should be taken to install the recess box in the correct orientation to accommodate grille. Note the position of the electrical entry knockouts and orient recess box according to Figure # 1. Ensure all required clearances are met.

Ensure recess box flanges are flush with the finished wall surface. For new construction, the sides of the recess box are marked with guidelines to allow for ½” and 5/8 “ drywall thickness if drywall is to be added at a later date. Secure recess box to studs with screws using holes provided on sides or flange of recess box. Remove appropriate electrical knockout and secure supply wire using an approved strain relief connector leaving 6" of wire leads in the recess box.

STEP 3 - Mounting the Heater Assembly

Insert the heater assembly into the recess box ensuring that the tab on the heater assembly slides into the slot in the recess box. Ensure the heater assembly is fully seated and secure to the recess box using the captive screw provided.

STEP 4 –Electrical Connections

Route supply wires from circuit breaker through wall thermostat to heater. For models with built in thermostat route from circuit breaker to heater. Supply wire must be of two wire plus ground variety, with a rating capable of handling all heaters on the circuit. Supply wire should be rated for a minimum of 60C. Make electrical connection according to relevant diagrams shown on Figure # 2. Make connections using approved wire nut connectors and secure the grounding wire to the green ground screw on the heater chassis. On models with Register Style Front Grills only, a terminal box cover plate is provided. Insert the tabs of the cover plate into the slots and secure the other side of plate with the screws provided.

STEP 5 – Secure the Front Panel

If your unit has a built in thermostat remove the plug on the front panel. Fasten the Front Grill using the screws provided. It is important to note that the front grill is oriented in the required positions shown in Figure # 1 and on the Multi – Directional grille, the larger louvered portion is placed over the fan blade portion of the heater. For units with built in thermostat push knob onto thermostat shaft through plug hole.

Operation And Maintenance

For units with built in thermostats, rotate the thermostat knob fully clockwise. Heater should activate. When the room reaches the desired temperature, slowly rotate the knob counterclockwise until unit shuts off. The heater will automatically cycle around this preset temperature setting. All units contain an Automatic Reset High Temperature Cutout, which will shut the heater off in the event of abnormally high operating temperatures. In addition a Red Warning Light will activate providing a visual warning. If this condition exists, disconnect all power to the unit and call a licensed electrician for service. Do not use heater until the problem is determined and corrected. ENSURE POWER TO THE UNIT IS DISCONNECTED

PRIOR TO SERVICING OR PERFORMING CLEANING

Image 1
Contents Installation Instructions Recess BOX Wiring AccessPrior to Servicing or Performing Cleaning MULTI-DIRECTIONAL Grille OrientationAccessories Replacement PartsMULTI-DIRECTIONAL Grille

6100770000, 6100790000 specifications

Dimplex is renowned for its innovative heating solutions, and models like the Dimplex 6100790000 and 6100770000 are prime examples of the brand's commitment to quality and efficiency. These electric radiators are designed for effective space heating while ensuring user comfort and energy savings, making them a popular choice in modern homes.

The Dimplex 6100790000 is an electric panel heater that offers advanced features and technologies to provide efficient heating. One of its main features is its sleek and minimalist design, which allows it to blend seamlessly into any decor. The unit boasts a powerful heating capacity and is equipped with a precise electronic thermostat that ensures consistent warmth by maintaining the desired temperature. Additionally, it comes with a programmable timer, allowing users to set heating schedules according to their preferences, promoting energy savings while ensuring comfort.

The Dimplex 6100770000 shares many of the same attributes as its counterpart, offering an equally stylish and functional heating solution. One of the standout features of this model is its energy efficiency, which is achieved through innovative technology like the adaptive start function. This feature pre-heats the room just before the scheduled time, ensuring that the space reaches the desired temperature right on time without wasting energy.

Both models utilize advanced safety features, including overheat protection and tip-over switches, ensuring that users can enjoy effective heating with peace of mind. Moreover, they are lightweight and easy to install, making them suitable for various spaces, from living rooms to bedrooms or even offices.

In terms of user control, each unit is equipped with a user-friendly interface, allowing for easy adjustment of settings. The silent operation of these heaters ensures that they provide warmth without any disruptive noise, enhancing the overall comfort of the environment.

In summary, the Dimplex 6100790000 and 6100770000 are exemplary electric heaters that combine advanced features, energy-saving technologies, and a stylish design. Their efficient heating capabilities, programmable settings, and safety features make them ideal for anyone looking to enhance their indoor comfort while maintaining energy efficiency.