TROUBLESHOOTING
| Problem | 
 | Possible Cause | 
 | Possible Solution | 
| Circuit breaker/fuse trip often. | 1. | Excessive wire length causes | 1. | Do not use an extension cord. | 
| 
 | 
 | voltage to drop too much. | 
 | Link additional air hoses together | 
| 
 | 
 | 
 | 
 | to acquire additional length. | 
| 
 | 2. | Restricted air passages. | 2. | Check all air passages for clogs. | 
| 
 | 3. | Back pressure in pump head. | 3. | Have a qualified service technician | 
| 
 | 
 | 
 | 
 | replace check valve and/or | 
| 
 | 
 | 
 | 
 | pressure switch bleeder valve. | 
| Overheating. | 1. | Poor ventilation. | 1. | Relocate air compressor to an area | 
| 
 | 
 | 
 | 
 | with cool, dry, well circulated air. | 
| 
 | 2. | Dirty cooling surfaces. | 2. | Clean all cooling surfaces of pump | 
| 
 | 
 | 
 | 
 | and motor thoroughly. | 
| 
 | 3. | Leaking valve. | 3. | Have a qualified service technician | 
| 
 | 
 | 
 | 
 | replace worn parts and | 
| 
 | 
 | 
 | 
 | |
| Motor stalls. | 1. | Low voltage. | 1. | Do not use an extension cord. | 
| 
 | 
 | 
 | 
 | Link additional air hoses together | 
| 
 | 
 | 
 | 
 | to acquire additional length. | 
| 
 | 2. | Defective pressure switch | 2. | Have a qualified service technician | 
| 
 | 
 | bleeder valve. | 
 | replace defective pressure switch | 
| 
 | 
 | 
 | 
 | bleeder valve. | 
| 
 | 
 | 
 | 
 | 
 | 
| Pressure relief valve opens. | 1. | Air tank pressure has exceeded | 1. | Have a qualified service technician | 
| 
 | 
 | normal operating pressure. | 
 | replace pressure switch. | 
| 
 | 2. | Pressure switch is stuck. | 2. | Have a qualified service technician | 
| 
 | 
 | 
 | 
 | replace pressure switch. | 
| Motor will not run. | 1. | Air tank pressure exceeds preset | 1. | Motor will automatically start when | 
| 
 | 
 | pressure switch limit. | 
 | air tank pressure drops below 85 | 
| 
 | 
 | 
 | 
 | PSI pressure of air tank. | 
| 
 | 2. | Motor overload protection has been | 2. | Replace blown fuse or reset circuit | 
| 
 | 
 | Tripped. | 
 | breaker. Do not use a fuse or | 
| 
 | 
 | 
 | 
 | circuit breaker with higher rating | 
| 
 | 
 | 
 | 
 | than specific for your circuit | 
| 
 | 
 | 
 | 
 | branch. Check for proper fuse; | 
| 
 | 
 | 
 | 
 | 15 AMP Buss fuse is acceptable. | 
| 
 | 3. | Air compressor attached to an | 
 | Do not use an extension cord. | 
| 
 | 
 | extension cord. | 
 | Link additional air hoses together | 
| 
 | 
 | 
 | 
 | to acquire additional length. | 
| 
 | 
 | 
 | 
 | Disconnect other applications from | 
| 
 | 
 | 
 | 
 | circuit. | 
| 
 | 
 | 
 | 
 | Operate air compressor on a dedi- | 
| 
 | 
 | 
 | 
 | cated circuit. | 
| 
 | 
 | 
 | 
 | Bleed line by moving pressure | 
| 
 | 
 | 
 | 
 | switch lever to OFF position before | 
| 
 | 
 | 
 | 
 | restarting. If bleeder valve does | 
| 
 | 
 | 
 | 
 | not open, replace bleeder valve. | 
| 
 | 
 | 
 | 
 | Have a qualified service technician | 
| 
 | 
 | 
 | 
 | clean or replace motor. | 
| SKU 94355 | For technical questions, please call  | PAGE 14 |