Dometic 595 SERIES Discharge Duct & Ceiling Template Installation, Installation of electronic con

Page 8

INSTALLATION INSTRUCTIONS

6.DISCHARGE DUCT & CEILING TEMPLATE INSTALLATION

A.Remove the air box and mounting hardware from their carton. The upper duct is shipped inside the lower duct

which is part of the ceiling template.

FIG. 8

B.Remove the upper duct from the ceiling template and locate it over the blower discharge.

Note: The edge without the flange installs toward the rear and side of the opening.

C.Use two of the sharp pointed sheet metal screws to hold the duct to the base pan. The holes are pre-punched in

the pan for each location.

D.Check gasket alignment over roof opening and adjust if necessary (roof gasket centers over opening). Unit may

be moved from below by lifting and sliding.

E.Reach up into the return air opening and pull the conduit power cable down for later connection. See FIG. 9.

F.Measure the ceiling thickness:

1.If the distance is 2” to 3” remove the perforated tabs from the bottom duct only.

2.If the distance is 3” to 4” install ducts as received.

3.If the distance is 4” to 6” (maximum thickness), optional Duct Kit and Bolt Kit are available:

Duct Kit

(Part No. 3106775.004)

Bolt Kit

(Part No. 3100895.006)

G.Take the ceiling template and slide the lower unit over the upper duct.

H.Hold the ceiling template with one hand and with the other, install the four 1/4” mounting bolts through the template and into the base pan. See FIG. 10.

1.Finger-tighten the four (4) bolts and check alignment. There should be an equal opening on each side and

the rear flange must be tight against the roof opening.

2.Evenly tighten the bolts to a torque of 40 to 50 inch pounds. This will compress the roof gasket to ap-

proximately 1/2”.

FIG. 10

FIG. 9

If bolts are left loose there may not be an adequate roof seal or if over tightened, damage may occur to the air conditioner base or ceiling template. Tighten to torque specifications listed in this manual.

Center Unit From Below

Note: In some applications it may be necessary to extend the 6 pin cable. Order cable number 3105584.001 if needed.

7. Installation of electronic con-

Image 8
Contents This manual must be read and understood Dommages matériels Or property damage57908.321 59516.603 57915.522 59016.531 57915.422 59016.521 59516.601General Information This AIR Conditioner is Designed forSpecifications Precautions Choosing Proper Location for the AIR ConditionerNormal Location Other LocationsInstallation Instructions After Location has Been Selected Roof PreparationCeiling Opening Requirements Opening PreparationDometic Comfort Control Center & Cable Installation LocationControl Cable Installation Placing the AIR Conditioner on the RoofDischarge Duct & Ceiling Template Installation Installation of electronic conTrol kit Wiring of SystemConnection of LOW Voltage Wires System CONFIGURATION, Reset & Checkout Electronic Control KIT ConfigurationSystem Reset System CheckoutAIR BOX Installation Two Zone ConfigurationAIR Conditioning Unit Installation Instructions Mounting PartsElectronic Control KIT