Harbor Freight Tools 95386 operating instructions Figure G, See Figure H

Page 12

3.Make sure the Drain Valve (65) is closed. (See Figure G.)

DRAIN

VALVE (65)

Figure G

ON/OFF

PRESSURE

SWITCH (55)

TANK

AIR OUTLET

PRESSURE

GAUGE (54)OUTLET VALVE (63) PRESSURE

GAUGE

(60)

FIGURE H

4.Make sure the “On/Off” Pressure Switch (55) is DOWN in its OFF position. Then, plug the Power Cord (64) into the nearest 120 volt, grounded, electrical outlet.

(See Figure H.)

5.Pull UP on “On/Off” Pressure Switch (55) to start the Compressor. (See Figure H.)

6.Allow the Compressor to build up from 80 PSI to 115 PSI as indicated on the Tank Pressure Gauge (54). Set the appropriate air pressure output for the air tool being used. Pull out and then turn the pressure adjustment knob above the Outlet Pressure Gauge (60) to the left to increase output air pressure or to the right to decrease output air pressure. Once the pressure level reaches the recommended

SKU 95386

For technical questions, please call 1-800-444-3353.

Page 12

Image 12
Contents AIR Compressor For technical questions, please callProduct Specifications General Safety RulesSave this Manual Work AreaElectrical Safety Personal SafetyTool USE and Care Service GroundingGrounded Tools Tools with Three Prong Plugs Double Insulated Tools Tools with TWO Prong Plugs Figure aExtension Cords See Figure C, nextSee Figure C Symbology Specific Safety Rules Do not allow children to use or play with this product Do not alter or remove the factory sealed Safety Valve Industrial applications must follow Osha requirementsUnpacking Operating InstructionsFigure D TOP ViewFigure G See Figure HReset Button Inspection and Maintenance WarrantyParts List DescriptionAssembly Diagram Please Readthe Following Carefully