Operation
Caution: Prior to use, inspect the compressor for any damaged parts or unsafe condi- tions. Make any necessary repairs before using again.
Turning Compressor On
1.Verify Tank Drain Valve
2.Verify oil level is correct.
3.Verify that the Safety Valve
4.Turn the Air Flow Valve
5.Plug the power cord into an electrical grounded 115 Volt AC electrical receptacle.
6.Rotate the Power Switch
NOTE: Allow the pressure to build up to at least 80 PSI before using air.
NOTE: Motor will not start if tank pressure is already between
7.Open the Air Flow Valve
The operation of the compressor is automatic, as controlled by the internal pressure switch. When the pressure drops below its operating range the compressor turns on. When the pressure is above 115 PSI, the compressor shuts off.
Warning;The compressor will become very hot during operation. Do not touch the cyl- inder area of the compressor, or allow flammable materials to come in contact with the cylinder area.
Adjusting Pressure Gauge and Pressure Adjustment Screw
Caution: The Pressure Switch is adjustable but changes to the pressure levels are not recommended; any change to the automatic ON/OFF pressure levels will cause addi- tional stress on the motor which may shorten motor life.
Adjusting Air Output
1.When the Air Flow Valve
2.Turn the Air Flow Valve to the appropriate pressure.
Maintenance
Warning: Do not make any repairs, adjustments, or maintenance on the air compressor unless it is disconnected from the electrical power and the tank pressure is released.
Maintenance should always be performed by a qualified technician.
REV 02/07
SKU 94734 | For technical questions, please call | Page 8 |