Harbor Freight Tools 90234 Inspection and Maintenance, Please Read the Following Carefully

Page 13

INSPECTION AND MAINTENANCE

1. WARNING! Always unplug the Air Compressor from its electrical outlet before performing any inspection, maintenance, or cleaning.

2.Before each use: Inspect the general condition of the Air Compressor. Check for misalignment or binding of moving parts, cracked or broken parts, damaged wiring, damaged air hose, and any other condition that may affect its safe opera- tion. If abnormal noise or vibration occurs, have the problem corrected before further use. Do not use damaged equipment.

3.Daily: Make sure the level of compressor oil is adequate. For instructions on checking and, if necessary, filling the Air Compressor with oil see pages 9 and 10 of this manual.

4.Daily: Purge the Tank (part #50) daily of all air and moisture to prevent corro- sion. To do so, unscrew the Tank Drain Valve (part #59) two to three turns. Do not unscrew the Tank Drain Valve more than three turns. When all the air pressure and moisture is released from the Tank, retighten the Tank Drain Valve.

(See Figure F.)

5.Store the Air Compressor in a clean, dry, location.

PLEASE READ THE FOLLOWING CAREFULLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTUER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.

SKU 90234

PAGE 13

Image 13
Contents Compressor General Safety Rules Product SpecificationsSave this Manual Work AreaPersonal Safety Electrical SafetyTool USE and Care Grounding ServiceGrounded Tools Tools with Three Prong Plugs Figure a Double Insulated Tools Tools with TWO Prong Plugs Specific Safety Rules SymbologyIndustrial applications must follow Osha requirements Operating Instructions UnpackingFigure D Figure F Figure G Please Read the Following Carefully Inspection and MaintenanceDescription Qty Parts ListParts List Assembly Diagram