battery charger is designed to have unmatched safety for protecting users from shock and other hazards when used as directed. Accordingly, it is important for users to read the following instructions carefully.

Do not charge non-rechargeable batteries like alkaline, carbon-zinc, or non-rechargeable lithium.

Remove all batteries from the charger before plugging in AC/DC adapter.

Make sure battery contacts are clean and there is no debris in the charger.

Do not short-circuit the contacts with metal objects.

Use only with Dell 70W or 90W AC/DC adapter, or the AC/DC adapter provided with this charger(optional).

Put the battery tightly into the battery station to ensure a good connection.

Observe the charging status LED and stop servicing immediately if it shows error signal (refer to the section 3.3).

Always store the charger in a cool and dry area.

3. Operation

3.1.To power the charger, connect the DC tip of the AC adapter to the socket on the back of the charger, then plug the AC connector of the adapter into a properly grounded outlet. The battery charger is ready to use.

3.2.Insert a battery pack into either bay.

The battery’s charging time will vary according to its charge status and WHr capacity.

3.3. LED Status

State

LED signal

Meaning

 

 

 

Charging

Red

Charging

 

 

 

Fully charged

Green

Charging complete

 

 

 

Under Voltage Fault

Red blinking

Pack voltage < 10.0 V

 

 

 

Over Temperature Fault

Red blinking

Pack temperature >117.5˚F(47.5˚C)

 

 

 

Constant charging

Red blinking

Constant charging time >

time Fault

 

120 minutes

 

 

 

Note: When the LED is red blinking, the internal circuit automatically stops the charging process.

For safety purpose, remove the battery from the charger bay and disconnect the DC power source from the charger. The red blinking LED indicates that the battery is faulty or excessively worn-out.

4. Certification

The battery charger is manufactured to comply with part 15 of the FCC Rules.

5. Specifications

Charging Rate: 2.6A Max.

Charging Time: 1.5~2.5 hours for two batteries

Power Requirement: Dell 70W, 90 W AC/DC adapter

Operating Temperature: 32~104˚F ( 0 ~ 40˚C)

Protection for Safety: Over-temperature/current/voltage-protection

Dimensions: 6.7 x 4.7x 2.2 (inch) or 170 x 120 x 55 (mm)