Bryant 552A, 556A Accessory Usage, VII. Make Piping Connections, Install LIQUID-LINE Filter Drier

Page 4

TABLE 1—REFRIGERANT CONNECTIONS AND RECOMMENDED LIQUID AND VAPOR TUBE DIAMETERS (IN.)

UNIT SIZE

LIQUID

 

VAPOR

 

VAPOR (LONG LINE)

Connection Diameter

 

Tube Diameter

Connection Diameter

 

Tube Diameter

Connection Diameter

Tube Diameter

 

 

 

018, 024

3/8

 

3/8

5/8

 

5/8

5/8

3/4

030, 036

3/8

 

3/8

3/4

 

3/4

3/4

7/8

042, 048

3/8

 

3/8

7/8

 

7/8

7/8

1-1/8

060

3/8

 

3/8

7/8

 

1-1/8

7/8

1-1/8

 

 

 

 

 

 

 

 

 

NOTES:

1.Tube diameters are for lengths up to 50 ft. For tubing lengths greater than 50 ft, consult the Application Guideline and Service Manual— Air Conditioners and Heat Pumps Using Puron® .

2.Do not apply capillary tube indoor coils to these units.

TABLE 2—ACCESSORY USAGE

 

 

 

 

 

 

 

 

REQUIRED FOR

REQUIRED FOR

REQUIRED FOR

 

ACCESSORY

LOW-AMBIENT

LONG-LINE

SEA COAST

 

APPLICATIONS

APPLICATIONS*

APPLICATIONS

 

 

 

 

(BELOW 55°F)

(OVER 50 FT)

(WITHIN 2 MILES)

 

Crankcase Heater

Yes

Yes

No

 

Evaporator Freeze Thermostat

Yes

No

No

 

Winter Start Control

Yes†

No

No

 

Accumulator

No

No

No

 

Compressor Start Assist

Yes

Yes

No

 

Capacitor and Relay

 

 

 

 

 

MotorMaster® Control,

 

 

 

 

or

Yes

No

No

 

Low-Ambient Pressure Switch

 

 

 

 

Wind Baffle

See Low-Ambient Instructions

No

No

 

Coastal Filter

No

No

Yes

 

Support Feet

Recommended

No

Recommended

 

Liquid-Line Solenoid Valve

 

 

 

 

or

No

See Long-Line Application Guideline

No

 

Hard Shutoff TXV

 

 

 

 

Ball Bearing Fan Motor

Yes‡

No

No

*For Tubing Sets between 50 and 175 ft, refer to the Application Guideline and Service Manual— Air Conditioners and Heat Pumps Using Puron® .

† Only when low-pressure switch is used.

‡ Required for low-ambient controller (full modulation feature) and MotorMaster® Control only.

VII. MAKE PIPING CONNECTIONS

WARNING: Relieve pressure and recover all refrigerant before system repair or final unit disposal to avoid personal injury or death. Use all service ports and open all flow-control devices, including solenoid valves.

CAUTION: Do not leave system open to atmosphere any longer than minimum required for installation. POE oil in compressor is extremely susceptible to moisture absorption. Always keep ends of tubing sealed during installation.

CAUTION: If ANY refrigerant tubing is buried, provide a 6 in. vertical rise at service valve. Refrigerant tubing lengths up to 36 in. may be buried without further special consideration. Do not bury lines over 36 in. in length.

CAUTION: To prevent damage to unit or service valves observe the following:

• Use a brazing shield.

Wrap service valves with wet cloth or use a heat sink material.

Outdoor units may be connected to indoor section using accessory tubing package or field-supplied refrigerant grade tubing of correct size and condition. For tubing requirements beyond 50 ft, substan- tial capacity and performance losses can occur. Following the recommendations in the Application Guideline and Service Manual—Air Conditioners and Heat Pumps Using Puron® Refrig- erant will reduce these losses. Refer to Table 1 for field tubing diameters. Refer to Table 2 for accessory requirements.

There are no buried-line applications greater than 36 in.

If refrigerant tubes or indoor coil are exposed to atmosphere, they must be evacuated to 500 microns to eliminate contamination and moisture in the system.

A. OUTDOOR UNIT CONNECTED TO FACTORY- APPROVED INDOOR UNIT

Factory refrigerant charge is for a 15 ft line set. Outdoor unit contains correct system refrigerant charge for operation with ARI rated indoor unit. Check refrigerant charge for maximum effi- ciency. The charge must be adjusted based on the actual line set length. Add or subtract 0.6 oz/ft for line sets longer or shorter than 15 ft.

B. INSTALL LIQUID-LINE FILTER DRIER

CAUTION: Installation of filter drier in liquid line is required.

Refer to Fig. 6 and install filter drier as follows:

1.Braze 5-in. connector tube to liquid service valve. Wrap filter drier with damp cloth.

—4—

Image 4
Contents Installation Recommendations Safety ConsiderationsInstallation Dimensions II. Install on a SOLID, Level Mounting PADVI. Install TXV 556A Standard 552A/550A OP Tional TXV InstallationInstalling TXV in Place of Piston Replacing TXV on R-22 Indoor CoilAccessory Usage Install LIQUID-LINE Filter DrierVII. Make Piping Connections Outdoor Unit Connected to FACTORY- Approved Indoor UnitRefrigerant Tubing Sweat ConnectionEvacuate Refrigerant Tubing and Indoor Coil MinutesRoute Ground and Power Wires Connect Ground and Power WiresConnect Control Wiring Install Electrical AccessoriesCooling only Procedure Units with Cooling Mode Puron TXVCare and Maintenance Units with Indoor PistonsRequired LIQUID-LINE Temperature F Superheat ChargingRequired SUCTION-LINE Temperature PURON- Quick Reference Guide Typical 24-v Circuit Connections J1 Jumper
Related manuals
Manual 44 pages 56.75 Kb Manual 36 pages 60.78 Kb Manual 8 pages 52.27 Kb

550A, 552A, 556A specifications

The Bryant 556A is an advanced air conditioning unit that exemplifies energy efficiency, durability, and user convenience, making it a popular choice for homeowners and businesses alike. With its impressive SEER (Seasonal Energy Efficiency Ratio) rating, the Bryant 556A stands out for its ability to deliver exceptional cooling performance while minimizing energy consumption. This efficient model is designed to meet modern energy standards, ensuring lower utility bills and a reduced carbon footprint.

One of the key features of the Bryant 556A is its use of advanced technology, including a variable-speed compressor. This innovative component allows the system to adjust its cooling output based on the current temperature conditions, ensuring optimal comfort without excessive energy use. The variable-speed design also contributes to a quieter operation, providing a more serene indoor environment.

In addition to its energy-efficient compressor, the Bryant 556A is equipped with enhanced humidity control capabilities. This feature works to maintain an ideal level of humidity within your space, improving indoor air quality and overall comfort. The unit’s precision cooling technology constantly monitors and adjusts the airflow, preventing overcooling and ensuring a consistent temperature throughout your home or office.

Another notable characteristic of the Bryant 556A is its robust construction. Built to withstand various weather conditions, the unit includes a galvanized steel cabinet with a baked-on enamel finish, making it resistant to rust and corrosion. This durability ensures a long lifespan, providing homeowners with reliable cooling for many years.

Installation and maintenance of the Bryant 556A are also user-friendly, featuring a compact design that makes it easier to fit in tight spaces. The unit is compatible with Bryant’s Evolution control system, allowing for seamless integration with smart home technology for personalized comfort configurations. Additionally, regular maintenance is simplified with easily accessible service points, ensuring that the unit remains in peak condition.

Overall, the Bryant 556A combines efficiency, advanced technology, and durability, making it an ideal choice for those seeking a high-performance air conditioning solution. Whether in a residential setting or for commercial use, the Bryant 556A delivers consistent comfort and quality, paving the way for a more sustainable and enjoyable living environment.