PS1 Specifications |
|
| Sealed Models |
|
|
|
|
Continuous Power Rating |
| At 40° C | 2500 VA |
|
| At 25° C | 3000 VA |
AC Voltage / Frequency Output |
|
| 120 VAC 60 Hz |
AC Input Current Maximum | AC Transfer Switch | 50 amps AC | |
|
| Battery Charger | 16 amps AC with automatic |
Maximum AC Surge Current | Peak (1 millisecond) | 70 amps AC | |
|
| RMS (5 seconds) | 50 amps AC |
Maximum PV Array Wattage |
|
| 3300 watts DC stc rating |
PV Open Circuit Voltage |
| Maximum | 150 VDC |
MPPT Input Voltage Range |
|
| 44 to 135 VDC |
PV Array Ground Fault Protection |
|
| Standard - 80 amp DC |
Inverter Efficiency |
| Typical | 91% (not CEC Certified) |
|
| Peak | 93% |
MPPT Efficiency |
|
| 98% |
Overall System Efficiency |
| Typical | 89% |
|
| Peak | 92% |
Battery Voltage - Nominal |
|
| 48 VDC |
Minimum / maximum operating range |
|
| 40 to 60 VDC |
Battery Charge Rate |
| Inverter | 35 amps DC |
|
| MX60 | 60 amps DC |
AC Output Voltage Regulation |
| Typical | 5% |
|
| Nominal | 120 VAC |
AC Output Current |
| Inverting | 25.0 amps AC |
|
| Selling | 20.8 amps AC |
Total Harmonic Distortion |
| Inverting | 2% VAC THD |
|
| Selling | < 5% current THD per UL1741 conditions |
AC Transfer Switch Speed |
| Typical | < 16 Milliseconds |
Battery Temperature Sensor |
|
| Included |
Operating Temperature Range |
|
| |
Recommended Minimum Energy Storage |
| 4 kWHRS at 80% discharge | |
Recommended Batteries |
|
| Four AGM type 31 or type 27 sealed VRLA |
Communications |
|
| Optional MATE system display with RS232 port |
Enclosure Materials |
|
| Powder coated aluminum, stainless steel hardware |
Mounting |
|
| Wall mount, 16 on center studs |
Recommended Mounting Hardware |
|
| 5/16 x 2.5” Lag Bolts - three per side minimum |
System Enclosure Dimensions (H x W x D) |
| Unit | 31.3 x 17.25 x 12.9” (80 x 44 x 33 cm) |
|
| Shipping | 40.5 x 20.5 x 17.25” (103 x 52 x 44 cm) |
Battery Enclosure Dimensions (H x W x D) |
| Unit | 36.25 x 17.25 x 12.55” (92 x 44 x 32 cm) |
|
| Shipping | 43.25 x 20.25 x 16.75” (110 x 51 x 43 cm) |
System Weight |
| Unit | 107 lbs (49 kg) |
|
| Shipping | 117 lbs (53 kg) |
Battery Enclosure Weight (without batteries) | Unit | 29 lbs (13 kg) | |
|
| Shipping | 47 lbs (21 kg) |
Certifications |
|
| ETL certified to the UL1741 standard |
|
| UL1741 compliant | |
Warranty |
|
| 5 year limited repair warranty standard |
Field Installed Options |
|
| MATE or MATE2 remote system display |
|
|
| OBAC breakers for additional AC load circuits |
|
|
| OBPV breakers for PV array series string protection |
Vented Models
PS1-3000
3000 VA
3600 VA
120 VAC 60 Hz
50 amps AC
20 amps AC with automatic
70 amps AC
50 amps AC
3300 watts DC stc rating
150 VDC
44 to 135 VDC Standard - 80 amp DC 91% (CEC Certified) 93% 98% 89% 92%
48 VDC
40 to 60 VDC
45 amps DC
60 amps DC
5%
120 VAC
30.0amps AC
25.0amps AC 2% VAC THD
< 5% current THD per UL1741 conditions < 16 Milliseconds
Included
4 kWHRS at 80% discharge
Four AGM type 31 or type 27 sealed VRLA Optional MATE system display with RS232 port Powder coated aluminum, stainless steel hardware Wall mount, 16" on center studs
5/16 x 2.5” Lag Bolts - three per side minimum
31.3x 17.25 x 12.9” (80 x 44 x 33 cm)
40.5x 20.5 x 17.25” (103 x 52 x 44 cm)
36.25x 17.25 x 12.55” (92 x 44 x 32 cm)
43.25x 20.25 x 16.75” (110 x 51 x 43 cm) 107 lbs (49 kg)
117 lbs (53 kg)
29 lbs (13 kg)
47 lbs (21 kg)
ETL certified to the UL1741 standard UL1741 compliant
5 year limited repair warranty standard MATE or MATE2 remote system display OBAC breakers for additional AC load circuits OBPV breakers for PV array series string protection
2005 | OutBack Power Systems Inc. l 1328 |