Bryant 557A Welcome to Efficient Cooling Comfort, Important Facts, Operating Your AIR Conditioner

Page 2

WELCOME TO EFFICIENT

COOLING COMFORT

Congratulations on your excellent choice and sound invest- ment in home cooling comfort! Your new air conditioner rep- resents both the latest in engineering development and the culmination of many years of experience from one of the most reputable manufacturers of comfort systems. Your new unit is among the most energy-efficient and reliable air condition- ing products available today. To assure its dependability, spend just a few minutes with this booklet now. Learn about the operation of your air conditioner and the small amount of main- tenance it takes to keep it operating at its peak efficiency.

With minimal care, your air conditioner will provide you and your family with satisfying home comfort Ð both now and for years to come.

IMPORTANT FACTS

To better protect your investment and to eliminate unneces- sary service calls, familiarize yourself with the following facts:

WARNING: Improper installation, adjustment, alter- ation, service, maintenance or use can cause explosion, ®re, electrical shock or other conditions which may cause personal injury or property damage. Refer to this manual. For assistance or additional information consult a quali®ed installer, service agency, distributor, or branch. The quali®ed installer or agency must use only factory authorized kits or accessories when modifying this product.

·Your air conditioning system should never be operated with- out a clean air ®lter properly installed. Plan to inspect the ®lter periodically. A clogged air ®lter will increase operating costs and shorten the life of the unit.

·Supply-air and return-air registers should not be blocked. Drapes, furniture, and toys are some of the items commonly found obstructing grilles. Restricted air¯ow lessens the unit's efficiency and life span.

·Outdoor units must have unrestricted air¯ow. Do not cover the unit, lean anything against it, or stand upon it. Do not allow grass clippings, leaves, or other debris to accumulate around or on top of the unit. Maintain a 12-in. minimum clear- ance between the outdoor unit and tall grass, vines, shrubs, et cetera.

·Your multipurpose indoor thermostat is the control center for your air conditioning system. You should familiarize your- self with its proper operation. Attempting to control the sys- tem by other means Ð for instance, switching the electrical supply power ON and OFF Ð may cause damage to the unit.

·Thermostat ``jiggling'' causes rapid-cycling, which is poten- tially damaging to the compressor. Do not move the tempera- ture selector on the thermostat for any reason for at least 5 minutes after the compressor has shut off.

·You may ®nd that you can maintain greater personal com- fort by running the fan continuously. ``Air pockets'' can form due to the structure of the building, placement of registers, et cetera. These air pockets may be too cool or warm for your liking. Continuous fan operation minimizes any temperature differences. Also, systems equipped with electronic air clean- ers and/or humidi®ers offer the added bene®ts of having the air continuously cleaned year-round, and humidi®ed during the winter season.

·Your air conditioner will remove humidity from your home during the cooling season. After a few minutes of operation,

you should be able to see water trickle from the condensate drain of the cooling coil. Check this occasionally to be sure the drain system is not clogged. Of course, don't expect to see much drainage if you live in a very dry environment.

OPERATING YOUR AIR CONDITIONER

The operation of your air conditioning system is controlled by the indoor thermostat. You simply adjust the thermostat and it maintains the indoor temperature at the level you se- lect. Most thermostats for air conditioning systems have three controls. These are the temperature control selector, FAN switch, and SYSTEM switch.

The temperature control selector is a dial or button(s) that al- lows you to establish the degree of temperature that you wish to maintain for your personal comfort. Some thermostats pos- sess two temperature control selectors: one for setting the tem- perature desired during the cooling cycle, and one to set the heating operation temperature (if the accessory electric heater is used). Typical settings are 78 degrees Fahrenheit for cool- ing and 68 degrees for heating.

The FAN switch offers two options for controlling the blower: AUTO and ON. When set to AUTO, the blower will run during the time the air conditioner is operating. When the FAN switch is set at the ON position, the blower will run con- tinuously.

Typically, the SYSTEM switch on your thermostat offers the following selections: COOL, OFF, and HEAT. Your thermo- stat may also have a fourth selection, AUTO. The air condi- tioner will not operate when the SYSTEM switch is set at the OFF position. With the SYSTEM switch set at COOL, the cooling section of your comfort system will operate when the indoor temperature rises above the level that you wish to maintain. With the SYSTEM switch set at the HEAT posi- tion, the accessory electric heater will operate automatically whenever the indoor temperature falls below the level that you have selected.

The AUTO selection found on some thermostats provides for automatic changeover between cooling and heating cycles. With the SYSTEM switch set in the AUTO position, the cooling mode is activated when the indoor temperature rises above the thermostat cooling temperature setting, or the heating mode will be activated when the indoor temperature drops below the thermostat setting for the heating cycle.

COOLING CYCLE

When operating in the cooling cycle, your air conditioner will run until the indoor temperature is lowered to the level you have selected. On extremely hot days, your air conditioner will run for longer periods at a time and have shorter ``off'' periods than on moderate days.

The following are typical conditions that add extra heat and/or humidity to your home. Your air conditioner will work longer to keep your home comfortable under these conditions:

·Entrance doors are frequently opened and closed

·Laundry appliances are being operated

·A shower is running

·More than the usual number of people are present in the home

·More than the normal number of electric lights are in use

·Drapes are open on the sunny side of the home

Ð2Ð

Image 2
Contents Users information manual Operating Your AIR Conditioner Welcome to Efficient Cooling ComfortImportant Facts Cooling CycleHeating Cycle Performing Routine MaintenanceBefore YOU Request a ``SERVICE Call Check the AIR FilterFor the Record Regular Dealer MaintenanceWarranties

557A specifications

The Bryant 557A is a state-of-the-art air conditioning unit that combines efficiency, reliability, and advanced technology to meet the cooling needs of residential spaces. Designed with homeowners in mind, this model stands out for its impressive performance and energy-saving capabilities.

One of the main features of the Bryant 557A is its high Seasonal Energy Efficiency Ratio (SEER) rating, which indicates exceptional energy efficiency. With a SEER rating of up to 16, the Bryant 557A helps reduce energy bills while maintaining a comfortable indoor environment. Its two-stage cooling system allows for better temperature control, adapting to outdoor conditions and providing consistent comfort throughout the day and night.

This model is equipped with advanced technologies such as the Advanced Communicating System, which enables seamless communication between the air conditioner and compatible smart thermostats. This feature allows users to monitor and adjust their home temperature from anywhere, ensuring energy is not wasted when the house is unoccupied. Additionally, theBryant 557A incorporates a variable-speed compressor, which adjusts its speed based on the home's cooling requirements, delivering precise temperature management.

Durability is another hallmark of the Bryant 557A. Built with a heavy-duty cabinet and an efficient evaporator coil, this unit is designed to endure harsh weather conditions while providing reliable performance year after year. The compressor is also protected with sound insulation, reducing operating noise for a more pleasant home environment.

The Bryant 557A is environmentally friendly, as it utilizes R-410A refrigerant, which has a lower impact on the ozone layer compared to traditional refrigerants. This commitment to sustainability is increasingly important in today’s eco-conscious market, making Bryant a preferred choice for many homeowners.

Installation and maintenance of the Bryant 557A are streamlined thanks to its user-friendly design. Featuring easy-access panels and connections, HVAC technicians can perform routine maintenance with minimal hassle, helping to extend the life of the unit and enhance its operating efficiency.

In summary, the Bryant 557A offers an appealing combination of energy efficiency, advanced technology, durability, and environmental consideration, making it an excellent choice for anyone looking to upgrade their home cooling system. Whether battling summer heat or maintaining indoor air quality, the Bryant 557A delivers reliable performance and comfort throughout the seasons.