Porter-Cable 7418 instruction manual Replacement Parts, Motor, Extension Cord Selection

Page 6

300918- 08-13-02.qxd 9/13/02 3:25 PM Page 6

8.CLEAN UP ALL REMOVED PAINT and dust by wet mopping the floors. Use a wet cloth to clean all walls, sills and any other surfaces where paint or dust is clinging. DO NOT SWEEP, DRY DUST OR VACUUM. Use a high phosphate detergent or trisodium (TSP) to wash and mop areas.

9.AT THE END OF EACH WORK SESSION put the paint chips and debris in a double plastic bag, close it with tape or twist ties and dispose of properly.

10.REMOVE PROTECTIVE CLOTHING and work shoes in the work area to avoid carrying dust into the rest of the dwelling. Wash work clothes separately. Wipe shoes off with a wet rag that is then washed with the work clothes. Wash hair and body thoroughly with soap and water.

REPLACEMENT PARTS

When servicing use only identical replacement parts.

MOTOR

Many Porter-Cable tools will operate on either D.C., or single phase 25 to 60 cycle A.C. current and voltage within plus or minus 5 percent of that shown on the specification plate on the tool. Several models, however, are designed for A.C. current only. Refer to the specification plate on your tool for proper voltage and current rating.

CAUTION: Do not operate your tool on a circuit on which the voltage is not within correct limits. Do not operate tools rated A.C. only on D.C. current. To do so may seriously damage the tool.

EXTENSION CORD SELECTION

If an extension cord is used, make sure the conductor size is large enough to prevent excessive voltage drop which will cause loss of power and possible motor damage. A table of recommended extension cord sizes will be found in this section. This table is based on limiting line voltage drop to 5 volts (10 volts for 230 volts) at 150% of rated amperes.

If an extension cord is to be used outdoors it must be marked with the suffix W-A or W following the cord type designation. For example – SJTW-A to indicate it is acceptable for outdoor use.

Amperaje nominal indicado en la placa de especificaciones

TAMAÑOS DE CABLES DE SERVICIO RECOMENDADOS PARA

USO CON HERRAMIENTAS ELÉCTRICAS PORTÁTILES

Longitud del cordón en pies

115V

25 pies

50 pies

100 pies

150 pies

200 pies

250 pies

300 pies

400 pies

500 pies

230V

50 pies

100 pies

200 pies

300 pies

400 pies

500 pies

600 pies

800 pies

1000 pies

 

18

18

18

16

16

14

14

12

12

0-2

 

 

 

 

 

 

 

 

 

 

2-3

18

18

16

14

14

12

12

10

10

 

 

 

 

 

 

 

 

 

 

3-4

18

18

16

14

12

12

10

10

8

 

 

 

 

 

 

 

 

 

 

4-5

18

18

14

12

12

10

10

8

8

 

 

 

 

 

 

 

 

 

 

5-6

18

16

14

12

10

10

8

8

6

 

 

 

 

 

 

 

 

 

 

6-8

18

16

12

10

10

8

6

6

6

 

 

 

 

 

 

 

 

 

 

8-10

18

14

12

10

8

8

6

6

4

 

 

 

 

 

 

 

 

 

 

10-12

16

14

10

8

8

6

6

4

4

 

 

 

 

 

 

 

 

 

 

12-14

16

12

10

8

6

6

6

4

2

 

 

 

 

 

 

 

 

 

 

14-16

16

12

10

8

6

6

4

4

2

 

 

 

 

 

 

 

 

 

 

16-18

14

12

8

8

6

4

4

2

2

 

 

 

 

 

 

 

 

 

 

18-20

14

12

8

6

6

4

4

2

2

 

 

 

 

 

 

 

 

 

 

6

Image 6
Contents Instruction Manual Double Insulated Disc Grinder Personal Safety General Safety RulesElectrical Safety Work Area Service Tools USE and CareSpecific Safety Rules and Symbols Symbol DefinitionAdditional Safety Rules for Paint Removal Replacement Parts MotorExtension Cord Selection Functional Description AssemblyTo Install Auxiliary Handle ForewordTo Install Wheel Guard To Install Grinding WheelUsing a Disc Grinder OperationMaintenance Accessories PORTER-CABLE Limited ONE Year Warranty300918- 08-13-02.qxd 9/13/02 326 PM Canadian PORTER-CABLE Delta Service Centers