Porter-Cable 7556 Functional Description, Motor, Extension Cord Selection, Foreword

Page 8

MOTOR

Many Porter-Cable tools will operate on either D.C., or single phase 25 to 60 cycle A.C. current and voltage within plus or minus 5 percent of that shown on the specification plate on the tool. Several models, however, are designed for A.C. current only. Refer to the specification plate on your tool for proper voltage and current rating.

Do not operate your tool on a current on which the voltage is not within correct limits. Do not operate tools rated A.C. only on D.C. current. To do so may seriously damage the tool.

EXTENSION CORD SELECTION

If an extension cord is used, make sure the conductor size is large enough to prevent excessive voltage drop which will cause loss of power and possible motor damage. A table of recommended extension cord sizes will be found in this section. This table is based on limiting line voltage drop to 5 volts (10 volts for 230 volts) at 150% of rated amperes.

If an extension cord is to be used outdoors it must be marked with the suffix W-A or W following the cord type designation. For example – SJTW-A to indicate it is acceptable for outdoor use.

RECOMMENDED EXTENSION CORD SIZES FOR USE WITH PORTABLE ELECTRIC TOOLS

Length of Cord in Feet

 

115V

25 Ft.

50 Ft.

100 Ft.

150 Ft.

200 Ft.

250 Ft.

300 Ft.

400 Ft.

500 Ft.

 

230V

50 Ft.

100 Ft.

200 Ft.

300 Ft.

400 Ft.

500 Ft.

600 Ft.

800 Ft.

1000 Ft.

 

 

 

 

 

 

 

 

 

 

 

 

0-2

18

18

18

16

16

14

14

12

12

 

 

 

 

 

 

 

 

 

 

 

Rating

2-3

18

18

16

14

14

12

12

10

10

 

 

 

 

 

 

 

 

 

 

3-4

18

18

16

14

12

12

10

10

8

 

 

 

 

 

 

 

 

 

 

4-5

18

18

14

12

12

10

10

8

8

Ampere

5-6

18

16

14

12

10

10

8

8

6

 

 

 

 

 

 

 

 

 

 

6-8

18

16

12

10

10

8

6

6

6

 

 

 

 

 

 

 

 

 

 

8-10

18

14

12

10

8

8

6

6

4

Nameplate

 

 

 

 

 

 

 

 

 

 

10-12

16

14

10

8

8

6

6

4

4

 

 

 

 

 

 

 

 

 

 

12-14

16

12

10

8

6

6

6

4

2

 

 

 

 

 

 

 

 

 

 

14-16

16

12

10

8

6

6

4

4

2

 

 

 

 

 

 

 

 

 

 

 

16-18

14

12

8

8

6

4

4

2

2

 

 

 

 

 

 

 

 

 

 

 

 

18-20

14

12

8

6

6

4

4

2

2

 

 

 

 

 

 

 

 

 

 

 

FUNCTIONAL DESCRIPTION

FOREWORD

Porter-Cable drills are designed to drill holes of various sizes in wood and metal as indicated in the following chart:

Model No. of Drill

Type of Bit

Max. Dia. Hole

Material

 

 

 

 

 

 

 

 

Low

Twist Drill

1/2"

Steel

 

 

Speed

Auger Bit

13/4"

Wood

7556

 

 

Self Feed Bit

45/8"

Wood

 

 

High

Twist Drill

1/2"

Steel

 

 

Speed

Auger Bit

11/2"

Wood

 

 

 

Self Feed Bit

29/16"

Wood

 

 

 

 

 

 

Fig. A

8

Image 8
Contents Double Insulated Right Angle Drill Table of Contents Important Safety InstructionsSafety Guidelines Definitions California PropositionGeneral Safety Rules General Safety Rules Additional Specific Safety Rules Symbol Definition Functional Description MotorExtension Cord Selection ForewordCarton Contents AssemblyInstalling and Removing Drill BIT To Install Auxiliary HandleOperation To Start and Stop DrillHOW to Hold the Drill General DrillingDrilling Wood Drilling MetalTroubleshooting Guide Maintenance Keep Tool CleanFailure to Start LubricationService AccessoriesReplacement Parts Service and RepairsWarranty PORTER-CABLE Limited ONE Year WarrantyCanadian PORTER-CABLE Delta Service Centers