Porter-Cable 100H Functional Description, Replacement Parts, Motor, Extension Cord Selection

Page 6

907395 - 12-20-02.qxd 12/20/02 9:13 AM Page 6

REPLACEMENT PARTS

When servicing use only identical replacement parts.

MOTOR

Many Porter-Cable tools will operate on either D.C., or single phase 25 to 60 cycle A.C. current and voltage within plus or minus 5 percent of that shown on the specification plate on the tool. Several models, however, are designed for A.C. current only. Refer to the specification plate on your tool for proper voltage and current rating.

Do not operate your tool on a current on which the voltage is not within correct limits. Do not operate tools rated A.C. only on D.C. current. To do so may seriously damage the tool.

EXTENSION CORD SELECTION

If an extension cord is used, make sure the conductor size is large enough to prevent excessive voltage drop which will cause loss of power and possible motor damage. A table of recommended extension cord sizes will be found in this section. This table is based on limiting line voltage drop to 5 volts (10 volts for 230 volts) at 150% of rated amperes.

If an extension cord is to be used outdoors it must be marked with the suffix W-A or W following the cord type designation. For example – SJTW-A to indicate it is acceptable for outdoor use

Nameplate Ampere Rating

RECOMMENDED EXTENSION CORD SIZES FOR USE WITH PORTABLE ELECTRIC TOOLS

Length of Cord in Feet

115V

25 Ft.

50 Ft.

100 Ft.

150 Ft.

200 Ft.

250 Ft.

300 Ft.

400 Ft.

500 Ft.

230V

50 Ft.

100 Ft.

200 Ft.

300 Ft.

400 Ft.

500 Ft.

600 Ft.

800 Ft.

1000 Ft.

 

18

18

18

16

16

14

14

12

12

0-2

2-3

18

18

16

14

14

12

12

10

10

 

 

 

 

 

 

 

 

 

 

3-4

18

18

16

14

12

12

10

10

8

 

 

 

 

 

 

 

 

 

 

4-5

18

18

14

12

12

10

10

8

8

5-6

18

16

14

12

10

10

8

8

6

 

 

 

 

 

 

 

 

 

 

6-8

18

16

12

10

10

8

6

6

6

 

 

 

 

 

 

 

 

 

 

8-10

18

14

12

10

8

8

6

6

4

10-12

16

14

10

8

8

6

6

4

4

 

 

 

 

 

 

 

 

 

 

12-14

16

12

10

8

6

6

6

4

2

 

 

 

 

 

 

 

 

 

 

14-16

16

12

10

8

6

6

4

4

2

16-18

14

12

8

8

6

4

4

2

2

 

 

 

 

 

 

 

 

 

 

18-20

14

12

8

6

6

4

4

2

2

 

 

 

 

 

 

 

 

 

 

FUNCTIONAL DESCRIPTION

FOREWORD

The router is one of the most useful tools in the woodworking field. It may be used for many cutting and shaping operations such as slotting, mortising, dadoing, grooving, rabbeting, corner-rounding, beading, dovetailing, veining, inlay work, etc.

6

Image 6
Contents Español Página Française 100 H100 General Safety Rules Work AreaElectrical Safety Personal SafetyTools USE and Care Service Specific Safety Rules and Symbols For RoutersPorter-Cable Corporation Highway 45 NorthJackson, TN Motor Replacement PartsFunctional Description Extension Cord SelectionAssembly Installing and Removing the BITSelecting the BIT Operation Adjusting Depth of CUTConnecting to Power Source Attaching the Motor to the Router BaseUsing the Router Starting and Stopping the MotorEdge Guide Templet GuidesMaintenance Accessories PORTER-CABLE Limited ONE Year WarrantyCanadian PORTER-CABLE Delta Service Centers