Porter-Cable CPLDC2540P instruction manual How to Use Your Unit, Before Starting

Page 13

Dipstick: Indicates the amount of oil in the pump, the + mark indicates full and the - mark indicates oil needs to be added. See Oil paragraphs in the Maintenance section for instructions.

Motor Thermal Overload Protector (not shown): The motor has an automatic reset thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. The compressor will automatically restart after the motor cools.

Dipstick

Air Intake Filter (not shown): This filter is designed to clean air coming into the pump. This filter must always be clean and ventilation openings free from obstructions. See "Maintenance".

Check Valve: When the air compressor is

 

 

 

 

 

 

 

 

 

 

operating, the check valve is “open”, allowing

 

 

 

 

 

 

 

Pressure

compressed air to enter the air tank. When the

 

 

Release

 

 

 

Valve

 

air compressor reaches “cut-out” pressure, the

 

 

 

 

 

 

 

 

 

 

check valve “closes”, allowing air pressure to

 

 

 

 

Check

remain inside the air tank.

 

Valve

 

 

 

 

 

 

 

 

 

 

 

Pressure Release Valve: The pressure release valve located on the side of the pressure switch, is designed to automatically release

compressed air from the compressor head and the outlet tube when the air compressor

reaches “cut-out” pressure or is shut off. The

pressure release valve allows the motor to restart freely. When the motor stops running, air will be heard escaping from this valve for a few seconds. No air should be heard leaking when the motor is running, or continuous leaking after unit reaches “cut-out” pressure.

How to Use Your Unit

How to Stop:

1.Set the On/Auto/Off lever to “OFF”.

Before Starting

Break-in Procedure

Serious damage may result if the following break-in instructions are not closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the On/Auto/Off lever is in the "OFF" position.

2.Check oil level in pump. See “Oil” paragraph in the “Maintenance” section for instructions.

NOTE: Pull coupler back until it clicks to prevent air from escaping through the quick connect.

13- ENG

A02231

Image 13
Contents Instruction Important Safety Instructions Safety Guidelines DefinitionsRisk of Explosion or Fire HazardRisk from Flying Objects Risk of BurstingRisk to Breathing Risk of Electrical ShockRisk from Moving Parts Risk of BurnsRisk of Falling Hazard Risk of Unsafe Operation Glossary SpecificationsDuty Cycle CPLDC2540PTo Add Oil To Pump AccessoriesLocation of the Air Compressor InstallationAllow the Compressor to GET WET Grounding Instructions Improper Grounding can Result in Electrical ShockVoltage and Circuit Protection Extension CordsKnow Your Air Compressor Description of Operation OperationBefore Starting How to Use Your UnitBefore Each Start-Up How to StartTo Check Safety Valve MaintenanceCustomer Responsibilities To Drain TankOil CheckingMotor Air Filter Inspection and ReplacementTo Replace Regulator Service and AdjustmentsStorage Problem Cause Correction TroubleshootingPressure reading Problem Cause Correction Problem Cause Correction Limited Warranty