Porter-Cable CPFAC2040P Maintenance, Before Each Start-Up, How to Start, To Check Safety Valve

Page 13

Before Each Start-Up:

1.Place On/Auto/Off lever to "OFF".

2.Turn the regulator knob counter- clockwise to set the outlet pressure to zero.

3.Attach hose and accessories.

NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket.

Risk of Bursting. Too much air pressure

causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

How to Start:

1.Turn the On/Auto/Off lever to "AUTO" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure.

2.Turn regulator knob clockwise to increase pressure and stop when desired pressure is reached.

The compressor is ready for use.

MAINTENANCE

Customer Responsibilities

 

Before

Daily or

 

each

after

 

each

 

use

 

use

 

 

Check Safety Valve

 

Drain Tank

 

Unit cycles automatically when

power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.

NOTE: See "Operation" section for the location of controls.

To Check Safety Valve

If the safety valve does not work

properly, over-pressurization may occur, causing air tank rupture or an explosion.

1.Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.

13 - ENG

D26130

Image 13
Contents Pancake Compressor Important Safety Instructions Safety Guidelines DefinitionsHazard Attachments & Accessories Electricity. Like any other electrically Result in serious burns Fire, Inhalation, Damage to Vehicle Surfaces Accessories SpecificationsGlossary Duty CycleInstallation AssemblyUnpacking Location of the Air Compressor Voltage and Circuit Protection Extension CordsKnow Your Air Compressor OperationDescription of Operation Air Compressor Pump not shown Before StartingHow to Start MaintenanceTo Check Safety Valve Before Each Start-UpTo Replace or Clean Check Valve Service and AdjustmentsTo Drain Tank To Replace Regulator Storage ENG D26130 Limited Warranty