Installing Rubber Foot Bumpers (Fig. 2)

1.Using a 3/8 inch wrench, remove the screws attaching the unit to the shipping pallet.

NOTE: These screws will be used to install the rubber foot bumpers.

2.Attach the four rubber foot bumpers (B) to the units legs (A) using the four screws (C) removed in step 1.

A

B

C

Fig. 2

Location of the Air Compressor

Locate the air compressor in a clean, dry, and well-ventilated area. The air filter must be kept clear of obstructions which could reduce air flow to the air compressor. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air. The air compressor head and shroud are designed to allow for proper cooling. If humidity is high, an air filter can be installed on the air outlet adapter to remove excessive moisture. Follow the instructions packaged with the air filter for proper installation.

Lubrication and Oil

This unit needs no lubrication or oiling.

Extension Cords

To avoid voltage drop, power loss, and overheating to the motor, use extra air hose instead of an extension cord. Low voltage can cause damage to the motor.

If an extension cord must be used:

use only a 3-wire extension cord that has a 3-blade grounding plug and a 3-slot receptacle that will accept the plug on the extension cord.

make sure the extension cord is in good condition.

the extension cord should be no longer than 50 feet.

the minimum wire size is 12 gauge (AWG). (Wire size increases as gauge number decreases. 10 AWG and 8 AWG may also be used. DO NOT USE 14 AWG or 16 AWG.)

Voltage and Circuit Protection

Refer to the specification chart for voltage and circuit protection requirements of your compressor. Use only a fuse or circuit breaker that is the same rating as the branch circuit on which the air compressor is operated. If the compressor is connected to a circuit protected by fuses, use only dual element time delay fuses.

8-ENG

Image 8
Contents Instruction Pancake Manual Compressor Read and Follow ALL Instructions Safety Guidelines DefinitionsImportant Safety Instructions Risk of Explosion or Fire What can Happen HOW to Prevent IT What can Happen HOW to Prevent ITHazard Risk of BurstingRisk of Electrical Shock What can Happen HOW to Prevent IT Risk from Flying Objects What can Happen HOW to Prevent ITRisk to Breathing What can Happen HOW to Prevent IT Risk from Moving Parts What can Happen HOW to Prevent IT Risk of Burns What can Happen HOW to Prevent ITRisk of Falling What can Happen HOW to Prevent IT Risk of Property Damage When Transporting CompressorSpecifications GlossaryDuty Cycle Model No CPF23400PDescription of Operation Installation Improper grounding can result in electrical shock Additional Regulators and ControlsAN Adapter BREAK-IN Procedures Operating ProceduresDaily Start-Up Checklist ProcedureMaintenance Service InstructionsAir Filter Inspection and Replacement Safety Valve InspectionMotor Motor Wiring DiagramStorage Troubleshooting Guide OVER-TIGHTENProblem Cause Correction 15-ENG Accessories FILTERS, REGULATORS, Lubricators17-ENG Limited Warranty This Warranty is not Transferable and does not Cover