SPECIFICATIONS

Model No.

C7550

Horsepower Peak

7.0

Voltage-Single Phase

240V

Minimum Branch Circuit Requirement

30 amps

*Fuse Type

Time Delay

Air Tank Capacity, Gallons

80 ASME, Vertical

Approximate Cut-in Pressure

140 PSIG

Approximate Cut-out Pressure

175 PSIG

SCFM @ 100 psig

15.6

SCFM @ 175 psig

15.2

GLOSSARY

Become familiar with these terms before operating the unit.

CFM: Cubic feet per minute.

SCFM: Standard cubic feet per minute; a unit of measure of air delivery.

PSIG: Pounds per square inch gauge; a unit of measure of pressure.

Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety. Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory. When the tank pressure drops to a certain low level the motor will restart

automatically. The low pressure at which the motor automatically restarts is called "cut-in" pressure. Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a certain high pressure before the motor automatically shuts off - protecting your air tank from pressure higher than its capacity. The high pressure at which the motor shuts off is called "cut-out" pressure.

Branch Circuit: Circuit carrying electricity from electrical panel to outlet.

To Lock Out Power: Place a lock on the line power switch so no one else can turn on the power.

DUTY CYCLE

This air compressor pump is capable of running continuously. However, to prolong the life of your air compressor, it is recommended that a

50%-75% average duty cycle be maintained; that is, the air compressor pump should not run more than 30-45 minutes in any given hour.

ACCESSORIES

Accessories for this unit are available at the store the unit was purchased.

D27042

8-ENG

Image 8
Contents Oil Lube Two Stage Air Compressor Safety Guidelines Definitions Important Safety InstructionsHazard Attachments & Accessories Electricity. Like any other electrically Result in serious burns Fire, Inhalation, Damage to Vehicle Surfaces Specifications AccessoriesGlossary Duty CycleAssembly Contents of CartonTools Required for Assembly UnpackingAnchoring of the Air Compressor InstallationLocation of the Air Compressor Wiring Instructions Voltage and Circuit ProtectionAir Distribution System AIR FlowDescription of Operation OperationKnow Your Air Compressor How to Use Your Unit Before StartingHow to Start Before Each Start-UpCustomer Responsibilities MaintenanceTo Check Safety Valve To Drain Tank OilChecking ChangingAdjusting Belt Tension Air Filter Inspection and ReplacementBelt Replacement Motor Pulley/Flywheel Alignment Air Compressor Pump Intake and Exhaust ValvesInspect Air Lines Fittings for Leaks Air compressor Head Bolts TorquingAdditional Service Service and AdjustmentsTo Replace or Clean Check Valve Storage Troubleshooting Problem Cause CorrectionPressure reading D27042 24-ENG 25-ENG D27042 Limited Warranty