Wagan 9925 user manual Troubleshooting, Maintenance, Description, Heat Dispersal, Specification

Page 4

Slim Line 75 Watt Power Inverter by Wagan Tech

USER’S MANUAL — Please read before using this equipment.

_______________________________________________________________________________________________________________________

TROUBLESHOOTING

Condition

Solution

Poor contact

Clean contact parts thoroughly

Battery voltage is

Start the engine to recharge the

too low

battery. Replace the battery if

 

needed.

Shutdown on

Reduce the wattage of inverter’s load

overload

 

Thermal shutdown

Allow the inverter to cool down by

 

reducing the load or turn it off for a

 

while.

Receptacle has no

Check the receptacle wiring.

power

 

MAINTENANCE

Very little maintenance is required to keep the inverter operating properly.

DESCRIPTION

150W Peak Power — allow you to power appliances that require a large amount of initial (peak) power to work (such as many TVs and motor-power equipments).

Low Battery Alarm — the inverter sounds an audible alarm then turns itself off if the source battery becomes too low.

Auto Shutdown/Reset Protection — the inverter temporarily shuts itself down to protect itself from overheating.

Overload/Short Circuit Protection — the inverter automatically turns itself off if the connected load is too high or if it shorts.

Fuse — the inverter comes with fuse/s already installed and easily changed if it is damaged.

HEAT DISPERSAL

The inverter generates heat while it is working. This is not a malfunction. However, if the inverter gets too hot while working, it will turn off by itself.

Position the inverter where air flows freely around it to allow the heat to disperse.

The inverter’s thermal protection prevents it from operating when its temperature exceeds 130 ± 10 θF / 55

± 5 θC.

SPECIFICATION

Name

Description

Input

12V (10-15V) DC

Output

115V AC

Output frequency

60 Hz

Output waveform

Modified Sine Waveform

Continuous power

75 Watt

Surge power

150 Watt

Efficiency

Approx. 90 %

No load current

< 0.2 A

Battery low alarm

10.5 ± 0.5 V DC

Battery low shutdown

10 ± 0.5 V DC

Alarm and thermal

130 ± 10 θF / 55 ± 5 θC

shutdown

 

DC fuse

15 A

AC output socket

1 outlets of 3-prong

Power switch

DC input ON/OFF control

Dimensions

5.5x4x1.5 in ³

Net Weight

0.5 lb

UPC 084367-

09925-9 Blue

UPC 084367-

09926-6 Gray

NOTE

All specifications are typical at nominal line, half load, and 77 θF / 25 θC unless otherwise noted. Specifications are subject to change without notice.

AC Outlets — allows you to power AC appliances.

© 2003 Wagan Corporation.

4

All Rights Reserved.

Wagan and Wagan.com are trademarks used by Wagan Corporation.

www.wagan.com

Printed in China

Image 4
Contents Item no Basic Operation RecommendationSafety Precaution Battery USEMeasuring the AC Voltage Troubleshooting MaintenanceSpecification DescriptionWagan Corp. Limited Warranty Registration Form